background image

1

e-Dial™: General Information & Features 

• 24ft (7.3m) of cable provided (user cuts to length) with flying leads for Power/ Ground

• Temp Range: -40⁰F to +176⁰F (-40⁰C to +80⁰C)  

• Ingress Protection: IP66 Rated

• High Visibility 4” LCD Digital Gauge Indicator 

• Resolution: 0.1% 

• Retrofittable on existing Rochester Magnetel and Taylor RoadMaster Gauges 

Safety Barrier: General Information & Features 

• Pre-installed 5ft (1.5m) cable for battery/power input

• Intrinsically Safe Electrical design

• Supply Voltage: 12-24 VDC 

• Max Input Current: 120mA

• Output Voltage Typical: 9.45V  

• Fused output

Download the Free Rochester Gauges e-Dial™ App Today!

DS-1857, Related Drawing

Revision A, 11/30/2020

Rochester Gauges LLC  

Customer Service, Toll Free (888) 723-5549

11616 Harry Hines Blvd. • P.O. Box 29242 • Dallas, TX 75229  

For more information visit

  

rochestergauges.com 

  

[email protected]

ISO 9001:2015 CERTIFIED

Содержание 6317-00001

Страница 1: ...User Manual...

Страница 2: ...The Measure of Excellence e Dial P N 6317 00001 ii...

Страница 3: ...ty Barrier General Information Features Pre installed 5ft 1 5m cable for battery power input Intrinsically Safe Electrical design Supply Voltage 12 24 VDC Max Input Current 120mA Output Voltage Typica...

Страница 4: ...packed in a cardboard box with a sticker indicating the model the main dimensions of the gauge the mounting position and tank dimensions for which the gauge has been manufactured and the product inte...

Страница 5: ...for 8 dial 3 3 4 Provided with the e Dial are two metal standoffs Screw the standoffs on the existing mounting bracket holes where the 4 dial was mounted on 5 Once the new standoffs are installed the...

Страница 6: ...arrier module to be installed in a nonhazardous location per SD 581 The safety barrier comes with 5ft 1 5m of cable preinstalled This is the power input for the device e Dial comes with a minimum 24ft...

Страница 7: ...pment references neutral as earth The end user shall ensure that there is no potential difference between the neutral connections between the e Dial and e Dial s Barrier L quipement fait r f rence au...

Страница 8: ...easurement Control and Laboratory Use Part 1 General Requirements Note For Canada ordinary locations listing certification Hazardous Locations Safety Standards IEC 60079 0 2017 Explosive atmospheres P...

Страница 9: ...7 DS 1857 Related Drawing Customer Service Toll Free 888 723 5549 Revision A 11 30 2020 Rochester Gauges LLC 11616 Harry Hines Blvd Dallas TX 75229...

Страница 10: ...for use in Class I Division 1 Groups C and D T4 or Zone 0 Group IIB T4 Hazardous Locations under the certification schemes and ratings noted below IECEx Global Certification e Dial Barrier Ex ia Ga II...

Страница 11: ...assessment of electrical and electronic products with respect to the restriction of hazardous substances Step Item e Dial Barrier e Dial System a Equipment group Groups C D Group IIB Groups C D Group...

Страница 12: ...sion A 11 30 2020 Rochester Gauges LLC Customer Service Toll Free 888 723 5549 11616 Harry Hines Blvd P O Box 29242 Dallas TX 75229 For more information visit rochestergauges com info rochestergauges...