2/22/2018
ROBOTIS e-Manual
http://emanual.robotis.com/docs/en/dxl/x/xm430-w210/
6/34
Address
Size
(Byte)
Data Name
Description
Access
Initial
Value
88
2
2nd Gain of Feed-
Forward
RW
0
90
2
1st Gain of Feed-
Forward
RW
0
98
1
DYNAMIXEL Bus
Watchdog
RW
0
100
2
Target PWM Value
RW
-
102
2
Target Current Value
RW
-
104
4
Target Velocity Value
RW
-
108
4
Acceleration Value of
Profile
RW
0
112
4
Velocity Value of Profile
RW
0
116
4
Target Position Value
RW
-
120
2
Count Time in
millisecond
R
-
122
1
Movement Status
R
0
123
1
Detailed Information of
Movement Status
R
0
124
2
Current PWM Value
R
-
126
2
Current Current Value
R
-
128
4
Current Velocity Value
R
-
132
4
Current Position Value
R
-
136
4
Target Velocity
Trajectory Generated by
Profile
R
-
140
4
Target Position
Trajectory Generated by
Profile
R
-
144
2
Current Input Voltage
R
-
146
1
Current Internal
Temperature
R
-
168
2
Indirect Address 1
RW
224
170
2
Indirect Address 2
RW
225
Back to Top ▲