3.2.2. FT 300-S Force Torque Sensor
The FT Sensor is designed for industrial applications. Always respect the following specified storage, transport and operating
environmental conditions:
Conditions
Values
Minimum storage / transit temperature
-30°C
Maximum storage / transit temperature
70°C
Minimum operating temperature
1
5°C
Maximum operating temperature
1
40°C
Humidity (non-condensing)
20-80% RH
Maximum vibration (storage / transit)
5G
Maximum vibration (operating)
2G
IP rating
IP 65
2,3
Other
l
Free from corrosive liquids or gases
l
Free from explosive liquids or gases
l
Free from powerful electromagnetic interference
1
Refer to the Signal Specifications section for details on temperature compensation range.
2
Dust-tight and protected against water jets.
3
IP Certification performed on the FT 300-S-UR-KIT, FT 300-S-OMRON-KIT, and FT 300-S-TM-KIT configurations only.
3.3. Mechanical installation
Choose the bracket corresponding to your finishing tool brand and align the dowel pin on the robot tool flange.
3.3.1. Mounting the Mirka finishing tool on e-Series robots
1. Mount the Robotiq Mirka bracket on the robot tool flange and secure it with the M6 screws and the tooth lock washers.
2. Align the Mirka finishing tool on the bracket.
3. Position the small jaws correctly on the sander and place the Belleville washers (with the convex side upward) and the M4
screws and fasten them loosely. Do not tighten them.
4. Position the large jaw on the sander and fasten the Belleville washers (with the convex side upward) and the M4 screws
tightly.