Step 2: Read Gripper status until the activation is completed
Request is: 09 03 07 D0 00 01 85 CF
Bits
Description
09
SlaveID
03
Function Code 03 (Read Holding Registers)
07D0
Address of the first requested register
0001
Number of registers requested (1)
85CF
Cyclic Redundancy Check (CRC)
Response (if the activation IS NOT completed): 09 03 02 11 00 55 D5
Bits
Description
09
SlaveID
03
Function Code 03 (Read Holding Registers)
02
Number of data bytes to follow (1 registers x 2 bytes/register = 2 bytes)
1100
Content of register 07D0 (GRIPPER STATUS = 0x11, RESERVED = 0x00): gACT = 1 for "Gripper Activation", gSTA = 1 for "Activation in
progress"
55D5
Cyclic Redundancy Check (CRC)
Response (if the activation IS completed): 09 03 02 31 00 4C 15
Bits
Description
09
SlaveID
03
Function Code 03 (Read Holding Registers)
02
Number of data bytes to follow (1 registers x 2 bytes/register = 2 bytes)
3100
Content of register 07D0 (GRIPPER STATUS = 0x31, RESERVED = 0x00): gACT = 1 for "Gripper Activation", gSTA = 3 for "Activation is
completed"
4C15
Cyclic Redundancy Check (CRC)