Robotiq 2-Finger Adaptive Gripper
Instruction Manual
Robotiq inc. © 2016
42
Register: FORCE
Address: Byte 5
Bits
7
6
5
4
3
2
1
0
Symbol
rFR
The force setting defines the final gripping force for the Gripper. The force will fix the maximum current sent to the motor while in motion. If the current limit
is exceeded, the fingers stop and trigger an object detection notification. See
for details on force control.
0x00 - Minimum force
0xFF - Maximum force
Info
Register byte 6 to 15 are reserved and should be set to zero.