Appendix B Information Registers
Here are definitions and more details on the information registers as mentioned in Section 5.
B.1 Motor Speed (MOT_SPD)
MOT_SPD (2 bytes in total)
Byte No.
byte1
byte2
Function
MOT_SPD
Register description:
(1) This register is used to configure the motor rotation direction and motor speed;
(2) The data storage adopts the big-endian format.
(3) Supported rotation speed:
(byte1==0x04) && (byte2==0xB0): speed 1200rpm, clockwise rotation;
(byte1==0x02) && (byte2==0x58): speed 600rpm, clockwise rotation;
(byte1==0x02) && (byte2==0x58): speed 300rpm, clockwise rotation;
If set with data other than the above described, the rotation speed of the motor is 0.
B.2 Ethernet(ETH)
ETH (22 bytes in total
)
Byte No.
byte1
byte2
byte3
byte4
byte5
byte6
byte7
byte8
Function
LIDAR_IP
DEST_PC_IP
Byte No.
byte9
byte10
byte11
byte12
byte13
byte14
byte15
byte16
Function
MAC_ADDR
port1
Byte No.
byte17
byte18
byte19
byte20
byte21
byte22
Function
port2
port3
port4
Register description:
(1) LIDAR_IP is the source IP address of the LiDAR. It takes 4 bytes
(2) DEST_PC_IP is the IP address of the destination PC. It takes 4 bytes
Содержание LiDAR RS-Bpearl
Страница 1: ...RS Bpearl User manual...
Страница 37: ...RS Bpearl User manual 37...
Страница 39: ...RS Bpearl User manual 39 Table 6 2 Time Offset of each Laser Point in the MSOP Packet in the Dual Return Mode...
Страница 47: ...RS Bpearl User manual 47 Figure A 7 Update Successful...
Страница 74: ...RS Bpearl User manual 74 Figure C 20 Fault Diagnosis...
Страница 79: ...RS Bpearl User manual 79 Appendix E Mechanical Drawings...
Страница 83: ...RS Bpearl User manual...