SECTION 13: S
ERVICING
I
NSTRUCTIONS
45 of 54
Tubes
Make s
u
re there are no cracks.
Make s
u
re t
u
bes are connected and s
u
spended sec
u
rely.
See Page 14, Figure 11
through Page 16, Section 6.2.1
.
Make s
u
re there is no dirt, sagging, bending or distortion.
Clean or replace as req
u
ired.
Gas Line
Check for gas leaks.
See Page 37, Figure 26
.
Combustion Chamber
Window
Make s
u
re it is clean and free of cracks or holes.
Clean or replace as req
u
ired.
Burner Head and Orifice
Clear of obstr
u
ctions (e
v
en spider
w
ebs
w
ill ca
u
se problems).
Caref
u
lly remo
v
e any d
u
st and debris from the b
u
rner.
Electrode
Replace if there are cracked ceramics, excessi
v
e carbon resid
u
e, or erosion
of the electrode.
The electrode gap sho
u
ld be 1/8” (3 mm).
Thermostat
There sho
u
ld be no exposed
w
ire or damage to the thermostat.
Suspension Points
Make s
u
re the heater is hanging sec
u
rely. The chains m
u
st hang
v
ertical.
Look for signs of
w
ear on the chain or ceiling.
See Page 14, Figure 11
.
Protective Grille (optional)
The grille m
u
st be sec
u
rely attached.
See Page 25, Section 7.5
through Page 25, Section 7.5.3
.
Pump
With p
u
mp operating, check for excessi
v
e
v
ibration or noise. Vibration is
u
s
u
ally a sign that the impeller is o
u
t of balance. T
u
rn off the system, ins
u
re
po
w
er is sh
u
t off and remo
v
e the inlet plate. Check the shaft seal and
replace it if
w
orn or missing.
With the Power off:
Check the inlet and o
u
tlet of the p
u
mp for blockage or excessi
v
e soot and
clean as necessary.
Check boots for cracking or deterioration and replace if necessary.
If a condensate drain is installed, check the condition of the drain and the
non ret
u
rn
v
al
v
e attached.
Check the condition of the motor anti
v
ibration mo
u
nts. Lift the motor from
the rear; look for breaks in the r
u
bber and replace if necessary.
Check the condition and operation of the press
u
re s
w
itch.
Wall Ta
g
If a
w
all tag is present, make s
u
re it is legible and acc
u
rate. Please contact
Roberts-Gordon E
u
rope Limited or yo
u
r ROBERTS GORDO
N
®
independent
distrib
u
tor if yo
u
need a
w
all tag.
See Page 4, Section 2.1
.
Содержание CoRayVac CRT-10
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 53: ...SECTION 14 TROUBLESHOOTING 47 of 54 14 1 Troubleshooting Flow Chart ...
Страница 61: ......