SECTION 3: C
LEARANCES
TO
C
OMBUSTIBLES
5 of 54
SECTION 3: CLEARANCES TO COMBUSTIBLES
3.1 Re
q
uired Clearances to Combustibles
Clearances are the req
u
ired distances that comb
u
s-
tible objects m
u
st be a
w
ay from the heater to pre-
v
ent serio
u
s fire hazards. Comb
u
stibles are
materials,
w
hich may catch on fire and incl
u
de com-
mon items s
u
ch as
w
ood, paper, r
u
bber, fabric, etc.
Maintain clearances to combustibles at all times
for safety.
Clearances for all heater models are located
on
Page 6, Figure 3
through Page 7, Figure 7
in this
man
u
al. Check the clearances on each b
u
rner for
the model heater being installed to make s
u
re the
prod
u
ct is s
u
itable for yo
u
r application and the clear-
ances are maintained. Read and follo
w
the safety
g
u
idelines belo
w
:
• Keep gasoline or other comb
u
stible materials
incl
u
ding flammable objects, liq
u
ids, d
u
st or
v
apors a
w
ay from this heater or any other
appliance.
• The stated clearances to comb
u
stibles represents
a s
u
rface temperat
u
re of 32°C abo
v
e room tem-
perat
u
re. B
u
ilding materials
w
ith a lo
w
heat toler-
ance (s
u
ch as plastics,
v
inyl siding, can
v
as, tri-
ply, etc) may be s
u
bject to degradation at lo
w
er
temperat
u
res. It is the installer’s responsibility to
ass
u
re that adjacent materials are protected from
degradation.
• Maintain clearances from heat sensiti
v
e
eq
u
ipment and
w
orkstations.
• Maintain clearances from
v
ehicles parked belo
w
the heater.
• Maintain clearances from s
w
inging and o
v
erhead
doors, o
v
erhead cranes,
v
ehicle lifts, partitions,
storage racks, hoists, b
u
ilding constr
u
ction, etc.
• In locations
u
sed for the storage of comb
u
stible
materials, signs m
u
st be posted to specify the
maxim
u
m permissible stacking height to maintain
req
u
ired clearances from the heater to the com-
b
u
stibles. Signs m
u
st be posted adjacent to the
heater thermostat. In the absence of a thermo-
stat, signs m
u
st be posted in a conspic
u
o
u
s
location.
• Cons
u
lt local Fire Marshal, Fire Ins
u
rance Carrier
or other a
u
thorities for appro
v
al of proposed
installation
w
hen there is a possibility of expos
u
re
to comb
u
stible airborne materials or
v
apo
u
rs.
• Hang heater in accordance to the minim
u
m s
u
s-
pension req
u
irements
on Page 14, Figure 11
.
• If the radiant t
u
bes m
u
st pass thro
u
gh the b
u
ild-
ing str
u
ct
u
re, be s
u
re that adeq
u
ate slee
v
ing and
fire stop is installed to pre
v
ent scorching and/or
fire hazard
WARNING
Fire Hazard
Keep all flammable objects, liquids and
vapors the minimum required clearances to
combustibles away from heater.
Some objects will catch fire or explode when
placed close to heater.
Failure to follow these instructions can result
in death, injury or property damage.
Содержание CoRayVac CRT-10
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 53: ...SECTION 14 TROUBLESHOOTING 47 of 54 14 1 Troubleshooting Flow Chart ...
Страница 61: ......