28
8.2 Fixture informations
Use this menu to read an useful information about the fixture.
Power On Time
---Select this submenu to read the number of operation hours.
Total Hours
--- The function shows the total number of the operation hours since the ColorSpot
575E AT has been fabricated.
Resetable Hours
--- The function shows the number of the operation hours that the ColorSpot
575E AT has been powered on since the counter was last reset.In order to reset this counter to
0,press [ENTER] twice.
Lamp On Time
--- Select this submenu to read the number of the operation hours with the lamp on.
Total Hours
--- The function shows the total number of the operation hours with the lamp on since
the ColorSpot 575E AT has been fabricated.
Resetable Hours
--- The function shows the number of the operation hours with the lamp on that the
ColorSpot 575E AT has been powered on since the counter was last reset.In order to reset this
counter to 0,press [ENTER] twice.
Lamp Strikes
--- Select this submenu to read the total number of the lamp strikes.
Total Hours
--- The function shows the total number of the lamp strikes since the ColorSpot
575E AT has been fabricated.
Resetable Hours
--- The function shows the number of the lamp strikes since the counter was last
reset.In order to reset this counter to 0,press [ENTER] twice.
Fixture Temperatures
--- Select this submenu to read the temperatures of the fixture:
Current
- Select this function to read the current temperatures of the fixture inside (Board
Temp.,Head Temp.)
Maximum nonresetable
- The function shows the max.temperatures of the fixture inside (Board
Temp.,Ambient Temp.,Near Lamp Temp.) since the ColorSp ot 575E AT has been fabricated.
Maximum resetable
- The function shows the maximum temperatures of the fixture inside (Board
Temp.,Ambient Temp.,Near Lamp Temp.) since the respective counter was last reset.In order to
reset desired counter to 0,press [ENTER] twice.
Measurement points:
Board Temp.
- temperature on the main board in the fixture base.Temperatures
below 66°C are not critical. 66° C and more lead to the lamp being switched off and the
fixture goes to "low power mode".Before switching the lamp on again (after 5 minutes),run
a total fixture reset.
Head Temp.
- temperature of the head inside.Temperatures below 83°C are not critical.
83° C and more lead to the lamp being switched off and the fixture goes to "low power
mode". Before switching the lamp on again (after 5 minutes),run a total fixture reset.
Please note that the ambient temperature should not exceed 40°C.
DMX Values
--- Select this function to read DMX values of each channel received by the fixture.
Product IDs
--- Select this function to read the MAC address or fixture code.
Software Version
--- Select this function to read the software version of the fixture modules:
IC1 B.
--- Main processor on the main board in the fixture base
IC2 B .
--- Pan processor on the main board in the fixture base
IC3 B.
--- Tilt procesor on the main board in the fixture base
IC4 B.
--- EEprom on the main board in the fixture base
IC1 L.
--- Processor 1 in the left arm of the fixture
IC2 L.
--- Processor 2 in the left arm of the fixture
IC1 R.
--- Processor 1 in the right arm of the fixture
IC2 R.
--- Processor 2 in the right arm of the fixture
IC1 DS
--- Display processor on the display module in the fixture base
IC2 DS
--- Memory on the display module in the fixture base
Содержание ColorSpot 575E AT
Страница 1: ...1 Version 1 4 ...
Страница 36: ...36 ...