5
Colour Wheel Error 1 (Colour Wheel Error 2)
The messages will appear after the reset of the colour wheel if this wheel is not located in the default position.
Gobo 1 Wheel Error 1 (Gobo 1 Wheel Error 2)
The messages will appear after the reset of the gobo wheel 1 if this wheel is not located in the default position.
Gobo 1 Index Error 1 (Gobo 1 Index Error 2)
The messages will appear after the reset of the gobo wheel 1 if the rotating gobo wheels are not located in the default
positions.
Gobo 2 Wheel Error 1 (Gobo 2 Wheel Error 2)
The messages will appear after the reset of the gobo wheel 2 if this wheel is not located in the default position.
Gobo 2 Index Error 1 (Gobo 2 Index Error 2)
The messages will appear after the reset of the gobo wheel 2 if the rotating gobo wheels are not located in the default
positions.
Effect Wheel Error 1 (Effect Wheel Error 2)
The messages will appear after the reset of the effect wheel if this wheel is not located in the default position.
Effect Index Error 1 (Effect Index Error 2)
The messages will appear after the reset of the effect wheel if the rotating effect wheels are not located in the default
positions.
Iris Error 1 (Iris Error 2)
The messages will appear after the reset of the iris if the iris lamellas are not located in the default positions.
Cyan Lamella Error 1 (Cyan Lamella Error 2)
The messages will appear after the reset of the CMY module if the cyan lamellas are not located in the default positions.
Magenta Lamella Error 1 (Magenta Lamella Error 2)
The messages will appear after the reset of the CMY module if the magenta lamellas are not located in the default positions.
Yellow Lamella Error 1 (Yellow Lamella Error 2)
The messages will appear after the reset of the CMY module if the yellow lamellas are not located in the default positions.
CTO Lamella Error 1 (CTO Lamella Error 2)
The messages will appear after the reset of the CTO module if the CTO lamellas are not located in the default positions.
Zoom Error 1 (Zoom Error 2)
The messages will appear after the reset of the zoom module if the module is not located in the default position.
Focus Error 1 (Focus Error 2)
The messages will appear after the reset of the focus module if the module is not located in the default position.
Pan Error 1 (Pan Error 2)
The messages will appear after the reset of the yoke if the yoke is not located in the default position.
Tilt Error 1 (Tilt Error 2)
The messages will appear after the reset of the head if the head is not located in the default position.
13. Technical specifications
Power supply:
Voltage: ........................................ 20/20/250V AC, 50/0Hz ~
Main fuses:
Live fuse: ......... T15 A@20V
Neutral fuse: .... T15 A@20V
Power consumption: ..................... 170 VA
Lamp:
Philips MSR GOLD 1200 FastFit ;00K;100W;750 hrs life, PGJX 50
Содержание ColorSpot 2500E AT
Страница 1: ...Color Spot 2500 AT USER MANUAL Version 1 7 ROBE Show Lighting s r o Czech Republic www robe cz ...