6. Fixed Installation Method
(1)Install the pump in a level and safe location.
(a) Utilizing using the screw holes on the bottom of the oil tank.
(b) Remove the rubber from the legs.
(c) Remove the adhesive from the screw area.
(2)
Ensure that the power voltage matches the voltage of the motor.
(3) :Ensure that the
Operation Switch is turned
“off”
before inserting the plug
of the power cord, otherwise when the Operation Switch is turned on, the
piston of the cylinder may extend and pressure may be exerted.
(4) :To prevent electric shock,
ensure that
earth wire is connected
into the plug.
(5)Connection to the Cylinder
Connect the pump and the cylinder using a high pressure hose or a high pressure pipe.
(A)When Connecting With a High Pressure Hose
Use the high pressure hose by directly screwing it into the normal pump side and using
a coupler to connect it to the cylinder side. Ensure that the taper screw area before for
the piping of the high pressure hose has been wrapped with a tape seal before screwing
it in.
(B)When Connecting With a High Pressure Pipe
Refer to pages for steel piping or wedge connectors in the general catalog,
or request an instruction manual for wedge connectors from a sales office.
Or, attach an air release valve to the tip of the pipe.
4-M6(depth9)
Rubber for legs
160
130
WARNING
WARNING
<*Method for Wrapping the Tape Seal>
Leave 1 to 2 threads exposed at the tip of the screw for the metal
fixture (R3/8) on one side of the high pressure hose. Wrap tape
around 1 or 2 times in the opposite direction of the screwing
direction (counter-clockwise).
Screw torque is 80 to 100 Nm.
Ensure that not dirt or foreign objects are adhered to the coupler
when connecting.
Wrapping direction
Hose Screwing direction
1 or 2 threads