Chapter 3 Arbitrary Waveform Output
DG4000 User's Guide
3-5
To Select Arbitrary Waveform
DG4000 allows users to select arbitrary waveforms stored in internal or external
memory for output. Press
Arb
Select Wform to select "Builtin", "Stored Wforms",
"Volatile Wform" or "DC" for output.
Built-In Waveform
Select from the 150 kinds of built-in arbitrary waveforms of DG4000 as shown in
the table below. Press
BuiltIn and select a kind ("Common", "Project", "SectMod,
"Bioelect", "Medical", "Standard", "Maths", "Trigonome", "Anti Trigonome" or
"Window"); the corresponding waveforms are displayed on the interface; use the
knob to select the desired waveform and press
Select to select the specified
waveform.
Table 3-1 Built-in Waveform Table
Name
Explanation
Common
DC
DC signal
AbsSine
Absolute value of a Sine
AbsSineHalf
Absolute value of half a Sine
AmpALT
Gain oscillation curve
AttALT
Attenuation oscillation curve
GaussPulse
Gauss pulse
NegRamp
Negative ramp
NPulse
Negative pulse
PPulse
Positive pulse
SineTra
Sine-Tra waveform
SineVer
Sine-Ver waveform
StairDn
Stair-down waveform
StairUD
Stair-up and stair-down waveform
StairUp
Stair-up waveform
Trapezia
Trapezoid waveform
Project
Содержание DG4062
Страница 1: ...RIGOL User s Guide DG4000 Series Function Arbitrary Waveform Generator Dec 2015 RIGOL TECHNOLOGIES INC...
Страница 2: ......
Страница 14: ...RIGOL XII DG4000 User s Guide...
Страница 31: ...Chapter 1 Quick Start RIGOL DG4000 User s Guide 1 5 116 7 153 160 7 104 9 12 100 Figure 1 4 Side View...
Страница 92: ......
Страница 128: ......
Страница 140: ......
Страница 150: ......
Страница 210: ......
Страница 213: ...Chapter 11 Remote Control RIGOL DG4000 User s Guide 11 3 3 4 5 6...
Страница 218: ......
Страница 222: ......