Chapter 2 Basic Waveform Output
DG4000 User's Guide
2-18
indicates current cursor location. Use the numeric keyboard to input the offset
value "5" and select the unit "mV
DC
" from the pop-up menu.
6.
Press
Width/Duty to highlight "Width". The lightspot above the number
indicates current cursor location. Use the numeric keyboard to input "200"
and select the unit "nsec" from the pop-up menu. At this point, the pulse duty
cycle changes accordingly.
7.
Press
Leading to highlight it. The lightspot above the number indicates
current cursor location. Use the numeric keyboard to input "75" and select the
unit "nsec" from the pop-up menu.
Press
Trailing to highlight it. The lightspot above the number indicates
current cursor location. Use the numeric keyboard to input "100" and select
the unit "nsec" from the pop-up menu.
8.
Press
Output1 at the front panel to turn the CH1 output on. At this point, the
instrument outputs the specified waveform from CH1 according to the current
configuration. Connect the output terminal of CH1 to the oscilloscope and the
waveform is as shown in the figure below.
Figure 2-4 To Output Pulse Waveform
Содержание DG4062
Страница 1: ...RIGOL User s Guide DG4000 Series Function Arbitrary Waveform Generator Dec 2015 RIGOL TECHNOLOGIES INC...
Страница 2: ......
Страница 14: ...RIGOL XII DG4000 User s Guide...
Страница 31: ...Chapter 1 Quick Start RIGOL DG4000 User s Guide 1 5 116 7 153 160 7 104 9 12 100 Figure 1 4 Side View...
Страница 92: ......
Страница 128: ......
Страница 140: ......
Страница 150: ......
Страница 210: ......
Страница 213: ...Chapter 11 Remote Control RIGOL DG4000 User s Guide 11 3 3 4 5 6...
Страница 218: ......
Страница 222: ......