Z
Y
X
O
1
b
d
/ PM6
KLT
15
15 (13)
25
40
dB(A)
50 Hz
66
69
71
60 Hz
68
72
73
kg
3 ~
27
32
49
1 ~
30
35
52
mm
476
407
507
593
mm
252
231
252
269
mm
246
286
246
281
Trouble Shooting:
1.
Motor starter cuts out pressure/vacuum pump:
1.1 Check that incoming voltage and frequency corresponds with the motor data plate.
1.2 Check the connections on the motor terminal block.
1.3 Incorrect setting on the motor starter.
1.4 Motor starter trips too fast.
Solution: Use a motor starter with a time delay trip (version as per IEC 947-4).
1.5 Filter cartridges on the exhaust side are contaminated.
1.6 The regulating valves are dirty causing excess pressure or vacuum.
2.
Insufficient suction or pressure capacity:
2.1 Inlet and/or exhaust filters are obscured.
2.2 Pipework is too long or too small.
2.3 Leak on the pump or on the system.
2.4 Blades are damaged.
3.
Pressure/vacuum pump operates at an abnormally high temperature:
3.1 Ambient or suction temperature too high.
3.2 Cooling air flow is restricted.
3.3 Problem as per 1.5 and 1.6.
4.
Unit emits abnormal noise:
4.1 The pump cylinder is worn.
Solution: send your complete unit off for repair to the supplier or approved service agent.
4.2 The regulating valve is noisy.
Solution: replace valve.
4.3 Blades are damaged.
Appendix:
Repair on Site: For all repairs on site an electrician must disconnect the motor so that an accidental start of the unit cannot happen.
All engineers are recommended to consult the original manufacturer or one of the subsidiaries, agents or service agents. The address of the nearest
repair workshop can be obtained from the manufacturer on application.
After a repair or before re-installation follow the instructions as shown under the headings ”Installation and Initial Operation”.
Lifting and Transport: To lift and transport the KLT 15 - KLT 40 the eye bolt on the pump must be used.
The weight of the pumps are shown in the accompanying table.
Storage: KLT units must be stored in dry ambient con-
ditions with normal humidity. We recommend for a
relative humidity of over 80% that the pump units should
be stored in a closed container with the appropriate
drying agents.
Disposal: The wearing parts (as listed in the spare parts
lists) should be disposed of with due regard to health and
safety regulations.
Spare parts lists:
E 480
➝
KLT 10 - KLT 40 (01) - (09)
E 482
➝
KLT 15 (13)
Noise level (max.)
Weight (max.)
Length
Width
Height
1.2001