START KI
24
TECHNICAL DATA
DESCRIPTION
START 24 KI
UM
Fuel
G20
G30
G31
Country of destination - appliance category
(+) - II2H3+
Country of destination - appliance category
MT - I3B/P
Type of appliance
B
11BS
Heating
Nominal heat input
26.70
kW
Nominal heat output
23.98
kW
Reduced heat input
10.70
kW
Reduced heat output
9.14
kW
Domestic hot water
Nominal heat input
26.70
kW
Nominal heat output
23.98
kW
Reduced heat input
8.30
kW
Reduced heat output
7.09
kW
Pn max - min working efficiency
89.8-85.4
%
Useful efficiency 30% Pn max (47° return)
89.5
%
Combustion efficiency
91.1
%
Loss at the shell with burner on (maximum output)
1.30
%
Loss to the chimney with burner on
8.90
%
Loss to the chimney with burner off
0.30
%
Heating maximum gas capacity
2.82
Sm
3
/h
2.10
2.07
kg/h
DHW maximum gas capacity
2.82
Sm
3
/h
2.10
2.07
kg/h
Heating minimum gas capacity
1.13
Sm
3
/h
0.84
0.83
kg/h
DHW minimum gas capacity
0.88
Sm
3
/h
0.65
0.64
kg/h
Flue gases temperature (maximum/minimum output)
138/96
135/98
138/101
°C
Mass flue gas flow rate** maximum output
16.115
15.033
15.589
g/sec
Mass flue gas flow rate** minimum output
15.926
14.182
15.004
g/sec
Flue gas capacity
47.345
44.020
45.655
Nm
3
/h
Air capacity
44.666
43.235
44.620
Nm
3
/h
Air excess index (
λ
) at maximum output
1.752
1.780
1.811
%
Air excess index (
λ
) at minimum output
4.347
4.137
4.300
%
CO
2
at maximum**/minimum**
6.7/2.7
7.9/3.4
7.6/3.2
%
CO S.A. at maximum**/minimum** lower than
80/60
110/70
45/80
ppm
NOx S.A. at maximum**/minimum** lower than
160/110
230/130
200/130
ppm
NOx class
2
heating maximum operating pressure
3
bar
Minimum pressure for standard operation
0.25-0.45
bar
Maximum permissible temperature
90
°C
Selection field of the domestic hot water temperature (± 3°C) 40-80
°C
Electrical supply
230-50
Volt-Hz
Maximum power drawn
55
W
Circulator electric power (1,000 l/h)
39
W
Pump head available to the system
227
mbar
for system capacity
1,000
l/h
Electrical protection level
X5D IP
Expansion tank
8
l
Expansion tank pre-charge
1
bar
DHW description
Maximum pressure
6
bar
Maximum pressure
0.15
bar
Hot water quantity with
∆
t 25°C
13.7
l/min
Hot water quantity with
∆
t 30°C
11.5
l/min
Hot water quantity with
∆
t 35°C
9.8
l/min
Selection field of the domestic hot water temperature (± 3°C)
37-60
°C
DHW minimum capacity
2
l/min
Flow limiter
10
l/min
(+) The installation of this product is allowed only in the destination Countries contained in the data plate, regardless of the present translation language.
(**) Check carried out with: pipe ø 130 length 0.5 m.
Содержание Start 24 KI
Страница 103: ...103 GR 1 Riello START KI Riello START KI OFF 1 1 5 bar OFF START KI 1 1 START KI...
Страница 106: ...START KI 106 1 9 1 10 A E B 1 1 5 bar a C C b D A B C D E 1 11 START KI G20 C...
Страница 109: ...109 A A 400 500 mm START KI G20 LPG 3 20 C...
Страница 110: ...START KI 110 OFF OFF 37 C 60 C stand by 5 6 5 C 15 2 10 C 5 C 30 C 30 24 3...
Страница 128: ...Cod 20115147 03 16 Ed 0...