42
RESIDENCE
PARAMETERS
UM
Residence KIS
METHANE GAS
*
LPG
*
Lower Wobbe index (at 15°C-1013 mbar)
0-Pñ6
45,67
70,69
1HW&DORUL¿F9DOXH
0-Pñ6
34,02
88
Supply nominal pressure
mbar (mm H
2
O)
20 (203,9)
37 (377,3)
Minimum supply pressure
mbar (mm H
2
O) 10
(102,0)
-
.,6
Burner: diameter/length
mm
70/86
70/86
Number of diaphragm holes
n°
1
1
Diaphragm holes diameter
mm
4,3
4,3
CH maximum gas capacity
6PñK
2,12
-
kg/h
-
1,55
DHW maximum gas capacity
6PñK
2,64
-
kg/h
-
1,94
CH minimum gas capacity
6PñK
0,38
-
kg/h
-
0,39
DHW minimum gas capacity
6PñK
0,38
-
kg/h
-
0,39
Number of fan rotations with slow ignition
rpm
5.500
5.500
Maximum number of CH fan rotations
rpm
6.200
6.000
Maximum number of DHW fan rotations
rpm
7.600
7.400
Minimum number of CH/DHW fan rotations
rpm
1.600
2.000
0D[QRI&+IDQURWDWLRQVLQ&FRQ¿JXUDWLRQƔ
Ø80-125
Ɣ
Ø80)
rpm
6.200
-
0D[QRI'+:IDQURWDWLRQVLQ&FRQ¿JXUDWLRQƔ
Ø80-125
Ɣ
Ø80)
rpm
7.600
-
0LQQRI&+'+:IDQUHYROXWLRQVLQ&FRQ¿JXUDWLRQƔ
Ø80-125
Ɣ
Ø80)
rpm
1.600
-
30 KIS
Burner: diameter/length
mm
70/125
70/125
Number of diaphragm holes
n°
1
1
Diaphragm holes diameter
mm
5,2
5,2
CH maximum gas capacity
6PñK
2,64
-
kg/h
-
1,94
DHW maximum gas capacity
6PñK
3,17
-
kg/h
-
2,33
CH minimum gas capacity
6PñK
0,52
-
kg/h
-
0,54
DHW minimum gas capacity
6PñK
0,52
-
kg/h
-
0,54
Number of fan rotations with slow ignition
rpm
5.500
5.500
Maximum number of heating fan rotations
rpm
5.800
5.600
Maximum number of DHW fan rotations
rpm
6.900
6.700
Minimum number of CH/DHW fan rotations
rpm
1.700
1.900
0D[QRI&+IDQURWDWLRQVLQ&FRQ¿JXUDWLRQƔ
Ø80-125
Ɣ
Ø80)
rpm
5.800
-
0D[QRI'+:IDQURWDWLRQVLQ&FRQ¿JXUDWLRQ
rpm
7.250
-
0D[QRI'+:IDQURWDWLRQVLQ&FRQ¿JXUDWLRQƔ
Ø80)
rpm
6.900
-
0LQQRI&+'+:IDQUHYROXWLRQVLQ&FRQ¿JXUDWLRQ
rpm
1.750
-
0LQQRI&+'+:IDQUHYROXWLRQVLQ&FRQ¿JXUDWLRQƔ
Ø80)
rpm
1.700
-
.,6
Burner: diameter/length
mm
70/125
70/125
Number of diaphragm holes
n°
1
1
Diaphragm holes diameter
mm
5,2
5,2
CH maximum gas capacity
6PñK
3,17
-
kg/h
-
2,33
DHW maximum gas capacity
6PñK
3,66
-
kg/h
-
2,69
CH minimum gas capacity
6PñK
0,52
-
kg/h
-
0,54
DHW minimum gas capacity
6PñK
0,52
-
kg/h
-
0,54
Number of fan rotations with slow ignition
rpm
5.500
5.500
Maximum number of CH fan rotations
rpm
6.900
6.900
Maximum number of DHW fan rotations
rpm
7.800
7.800
Minimum number of CH/DHW fan rotations
rpm
1.700
1.900
0D[QRI&+IDQURWDWLRQVLQ&FRQ¿JXUDWLRQƔ
Ø80-125
Ɣ
Ø80)
rpm
6.900
-
0D[QRI'+:IDQURWDWLRQVLQ&FRQ¿JXUDWLRQ
rpm
8.200
-
0D[QRI'+:IDQURWDWLRQVLQ&FRQ¿JXUDWLRQƔ
Ø80)
rpm
7.800
-
0LQQRI&+'+:IDQUHYROXWLRQVLQ&FRQ¿JXUDWLRQ
rpm
1.800
-
0LQQRI&+'+:IDQUHYROXWLRQVLQ&FRQ¿JXUDWLRQƔ
Ø80)
rpm
1.700
-
Содержание RESIDENCE 25 KIS
Страница 125: ...125 RESIDENCE 25 KIS 30 35 KIS 18 5 9 23 20 Fig 1 32 35 33 36 34 32 35 33 36 34 ...
Страница 137: ...137 RESIDENCE A B C D Fig 21 Fig 22 a b c A B d Fig 23 C ...
Страница 138: ......
Страница 139: ......