26
RESIDENCE
Boiler faults list
ERROR
CODE
FAULT
DESCRIPTION OF
ALARM TYPE
E010
ÀDPHORFNRXW$&)HOHFWURQLFIDXOW
GH¿QLWLYH
E011
H[WUDQHRXVÀDPH
transitional
E020
limit thermostat
GH¿QLWLYH
E030
fan fault
GH¿QLWLYH
E040
water transducer – load system
GH¿QLWLYH
E041
water transducer – load system
transitional
E042
water pressure transducer fault
GH¿QLWLYH
E060
domestic hot water probe fault
transitional
E070
ÀRZVHQVRUIDXOW
ÀRZVHQVRURYHUWHPSHUDWXUH
ÀRZUHWXUQVHQVRUGLIIHUHQWLDODODUP
transitional
GH¿QLWLYH
GH¿QLWLYH
E077
main zone water thermostat
transitional
E080
return line probe fault
return line probe overtemperature
outlet/return line probe differential alarm
transitional
GH¿QLWLYH
GH¿QLWLYH
E090
ÀXHJDVSUREHIDXOW
ÀXHJDVSUREHRYHUWHPSHUDWXUH
transitional
GH¿QLWLYH
E091
clean primary heat exchanger
transitional
--
water pressure low check system
transitional
--
water pressure high check system
transitional
--
boiler board communication lost
transitional
--
%86FRPPXQLFDWLRQORVW
transitional
List of combustion faults
ERROR
CODE
FAULT
DESCRIPTION OF ALARM TYPE
E021
ion alarm
7KHVHDUHWHPSRUDU\DODUPVWKDWLIWKH\RFFXUWLPHVLQDQKRXUWKH\EHFRPHGH¿QLWLYHWKH(DODUPLVGLV
-
played and is followed by post-purging for 45 seconds at the fan's maximum speed.
It is not possible to release the alarm before the end of the post-purging unless the boiler's power supply is
switched off.
E022
ion alarm
E023
ion alarm
E024
ion alarm
E067
ion alarm
E088
ion alarm
E097
ion alarm
E085
incomplete combustion
7KHVHDUHWHPSRUDU\DODUPVWKDWLIWKH\RFFXUWLPHVLQDQKRXUWKH\EHFRPHGH¿QLWLYHWKHODVWHUURUWRRFFXULV
displayed and is followed by a post-purging of 5 minutes at the fan's maximum speed.
It is not possible to release the alarm before the end of the post-purging unless the boiler's power supply is
switched off.
E094
incomplete combustion
E095
incomplete combustion
E058
mains voltage fault
These are temporary faults that restrict the ignition cycle.
E065
current modulation alarm
E086
ÀXHJDVHVREVWUXFWLRQDODUP
Temporary fault signalled during pre-purging. Post-purging is maintained for 5 min at maximum fan speed.
Содержание RESIDENCE 25 KIS