GENERAL INFORMATION

This manual, Code Doc-0071233 - Rev. 3 (09/2017) 

comprises 8 pages.

GENERAL INFORMATION

RANGE

MODEL

CODE

RIELLO 7200/3F - 800 HV PLUS

20136273

RIELLO 7200/3F - 1000 HV PLUS

20136274

RIELLO 7200/3F - 1500 HV PLUS

20136275

RIELLO 7200/3F - 2000 HV PLUS

20136277

RIELLO 7200/3F - 3000 HV PLUS

20052788

ACCESSORIES

For a complete list of accessories and details of their compatibil-

ity, refer to the Catalogue.

Dear heating engineer,

We would like to congratulate you on having recommended a 

R

 storage cylinder unit: a modern product that's capable of 

ensuring a high degree of reliability, efficiency, quality and safe-

ty.

While your technical skills and knowledge will certainly be more 

than sufficient, this booklet contains all the information that 

we have deemed necessary for the device's correct and easy in-

stallation.

Thank you again, and keep up the good work,

Riello S.p.A.

CONFORMITY

The 

R

 solar heaters comply with DIN 4753-3 and UNI EN 12897.

CONTENTS

The following symbols are used in this manual:

 

9

CAUTION! =

  Identifies  actions  that  require  caution  and 

adequate preparation.

 

0

STOP! =

 Identifies actions that you MUST NOT do.

GENERAL SAFETY INFORMATION

 

9

Check that the product is complete, undamaged and as or-

dered as soon as you receive it. Report any discrepancies or 

damage to the 

R

 dealer who sold it.

 

9

This product must be installed by a legally qualified heat-

ing engineer. On completion of the installation, the install-

er must issue the owner with a declaration of conformity 

confirming that the installation has been completed to the 

highest standards in compliance with the instructions pro-

vided by 

R

 in this instruction manual, and that it con-

forms to all applicable laws and standards.

 

9

This product must only be used for the purpose for which it 

is designed and made, as specified by 

R

R

 declines 

all responsibility, contractual or other, for damage to prop-

erty or injury to persons or animals caused by improper in-

stallation, adjustment, maintenance or use.

 

9

The product must be serviced at least once a year. Servicing 

must be arranged in advance with the 

R

 Technical Assis-

tance Service.

 

9

All servicing and repairs must be performed by a qualified 

heating engineer.

 

9

If water leaks from the storage cylinder, turn off the water 

supply and contact 

R

’s Technical Assistance Service or a 

qualified heating engineer immediately.

 

9

If the product is not going to be used for an extended peri-

od of time, contact the manufacturer’s Technical Assistance 

Service to have at least the following operations performed:

 

− Close the shut-off cocks for the domestic hot water circuit

 

− Shut down the boiler connected to the storage cylinder 

as instructed in its own manual

 

− Switch the storage cylinder OFF at the control panel (if 

fitted) and at the mains power switch

 

− Drain the central heating circuit and domestic hot water 

circuit if there is any risk of freezing.

 

9

This instruction manual is an integral part of the product. It 

must be kept safe and must ALWAYS accompany the product, 

even if it is sold to another owner or transferred to another 

user or to another installation. If you lose this manual, or-

der a replacement immediately. Keep the product purchase 

documents to be presented to the 

R

 authorised Technical 

Assistance Service to request a service call under warranty.

This manual, Code
- Rev.
comprises
pages.

ENGLISH

General information

GENERAL INFORMATION

General Safety Information . . . . . . . . . . . . . . . . . . . . . . 2

2 Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Description of the appliance . . . . . . . . . . . . . . . . . . . . . 3

Identification  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

System layout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Technical specifications. . . . . . . . . . . . . . . . . . . . . . . . . 4

INSTALLATION

Unpacking the product . . . . . . . . . . . . . . . . . . . . . . . . . 5

Installing the magnesium anodes. . . . . . . . . . . . . . . . . 5

Fitting the insulation (models 2000 - 3000). . . . . . . . . . 5

10 

Place of installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

11 

Installation in older systems and systems requiring 

modernisation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

12 

Water quality requirements. . . . . . . . . . . . . . . . . . . . . . 6

13 

Water connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

14 

Recycling and disposal  . . . . . . . . . . . . . . . . . . . . . . . . .8

END USER

15 Start-up  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

16 

Temporary shutdown  . . . . . . . . . . . . . . . . . . . . . . . . . .8

17 

Preparing for extended periods of disuse  . . . . . . . . . . .8

18 

External maintenance. . . . . . . . . . . . . . . . . . . . . . . . . .8

Содержание 7200/3F HV PLUS Series

Страница 1: ...cod Doc 0071233 rev 3 09 2017 7200 3F HV PLUS EN INSTALLATION OPERATION AND MAINTENANCE MANUAL ...

Страница 2: ... to prop erty or injury to persons or animals caused by improper in stallation adjustment maintenance or use 9 9The product must be serviced at least once a year Servicing must be arranged in advance with the R Technical Assis tance Service 9 9All servicing and repairs must be performed by a qualified heating engineer 9 9If water leaks from the storage cylinder turn off the water supply and contac...

Страница 3: ...ly water as there is a danger of freezing and over heating 0 0Do not use connections or safety devices or fittings expan sion vessels pipes insulation that are not specifically de signed and tested for use in solar water heating systems 0 0Do not allow children or infirm persons to operate the sys tem unsupervised 0 0Do not dispose of packaging material into the environment or leave it within the ...

Страница 4: ... 190 305 325 543 kg First magnesium anode Ø x length 32x700 mm Second magnesium anode Ø x length 32x400 32x700 mm Flange diameter external internal 290 220 mm Diameter length of sensor sockets 8 200 mm Sleeve for electric heating element 1 1 2 Ø Maximum operating pressure of storage cylinder 10 8 bar Maximum operating temperature 99 C Discharges according to EN 12897 2006 T 45 C am bient 20 C and ...

Страница 5: ...0 models Partially remove the cladding remove the washer and unscrew the anode holder plug in the sleeve using a spanner Insert the anode provided tighten the anode using a spanner and then put the washer back in position 7200 3F HV PLUS 2000 3000 models Before fitting the cladding unscrew the anode holder plug in the sleeve using a spanner Insert the anode provided and tighten the anode using a s...

Страница 6: ...e sure that the system is fitted with safety and con trol devices in accordance with applicable legislation and standards Make sure that the central heating circuit has been flushed out to remove all sludge and lime scale and has been vented and seal tested Make sure that a suitable water treatment system is in stalled if the quality of the supply recirculation water so demands refer to the refere...

Страница 7: ...250 1345 1455 mm D 670 760 800 820 865 mm E 600 690 730 750 795 mm F 350 350 435 410 475 mm G 240 240 280 250 190 mm H 790 790 1000 1100 1250 mm I 470 470 545 555 580 mm L 760 820 865 mm M 940 1075 1075 1085 1165 mm N 1130 1295 1290 1345 1455 mm O 1320 1610 1505 1670 1860 mm P 1510 1830 1720 1990 2265 mm Q 1810 2140 2120 2425 2700 mm Net weight with insulation 168 188 303 321 543 kg 9 9It is recom...

Страница 8: ... electricity supply ON at the mains power switch and at control panel switch if fitted 16 TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with exter nal temperatures above 0 C set the heater temperature control where available to the minimum value 9 9If the temperature to which the heater is exposed can fall below 0 C...