INSTALLATION
INSTALLATION
If disassembling is required, proceed in reverse order.
9
To finish the assembly, apply the serial number plate, rat-
ing plate and product plate, so that the tank can be easily
identified.
10
PLACE OF INSTALLATION
R
7200/3F HV PLUS
solar heaters can be installed in all rooms
not requiring a level of electrical protection of the device greater
than IP X0D.
≥ 0,3 m
≥ 0,3 m
≥ 0,3 m
≥ 0,6 m
≥ 0,7 m
NOTE:
the above-indicated dimensions are recommended for a
correct maintenance and access to the device.
11
INSTALLATION IN OLDER SYSTEMS AND SYSTEMS
REQUIRING MODERNISATION
When installing
R
7200/3F HV PLUS
storage cylinders in old
systems or systems requiring modernisation, always perform
the following checks.
− Make sure that the system is fitted with safety and con-
trol devices in accordance with applicable legislation and
standards
− Make sure that the central heating circuit has been
flushed out to remove all sludge and lime scale, and has
been vented and seal tested
− Make sure that a suitable water treatment system is in-
stalled if the quality of the supply/recirculation water so
demands (refer to the reference values listed in the table
alongside).
12
WATER QUALITY REQUIREMENTS
REFERENCE VALUES
pH
6-8
Electrical conductivity
less than 200 μS/cm (25°C)
Chlorine ions
less than 50 ppm
Sulphuric acid ions
less than 50 ppm
Total iron
less than 0.3 ppm
Alkalinity M
less than 50 ppm
Total hardness
less than 35°F
Sulphur ions
none
Ammonia ions
none
Silicon ions
less than 30 ppm
The values above ensure proper operation of the system. Refer
to the limit values specified in the current standards and regu-
lations on the installation site.