GENERAL INFORMATION

GENERAL INFORMATION

SYSTEM LAYOUT

UAC

EAF

SB

1

5

6

7

2

3

3

3

4

M

P

2

4

Storage cylinder

Probe/electronic anode pit (optional)

Flange for inspection/insertion of additional exchang-

ers

Probe pit

Thermometer connection

Insulation

Cover

M

 Guide

UAC

 

Domestic hot water outlet

EAF

 

Domestic cold water inlet

P

 Socket

SB

 

Storage cylinder drain

TECHNICAL SPECIFICATIONS

DESCRIPTION

7200/3F HV PLUS

800

1000

1500

2000

3000

Type of storage cylinder

Vertical, glazed

Heat exchanger layout

Horizontal

Storage cylinder capacity

749

955

1430

1990

2959

l

Useful non-solar volume (Vbu) (*)

420

490

790

1210

1745

l

Solar usable volume (Vsol) (**)

329

465

640

780

1214

l

Diameter of storage cylinder with insulation

990

990

1200

1300

1450

mm

Diameter of storage cylinder without insulation

790

790

1000

1100

1250

mm

Height with insulation

1875

2205

2185

2470

2680

mm

Height without insulation

1810

2140

2120

2425

2650

mm

Insulation thickness

100

mm

Total net weight

150

190

305

325

543

kg

First magnesium anode (Ø x length)

32x700

mm

Second magnesium anode (Ø x length)

-

32x400

32x700

mm

Flange diameter (external/internal)

290/220

mm

Diameter/length of sensor sockets

8/200

mm

Sleeve for electric heating element (***)

1" 1/2

Ø

Maximum operating pressure of storage cylinder

10

8

bar

Maximum operating temperature

99

°C

Discharges according to EN 12897:2006 

T=45 °C (am-

bient 20°C and storage at 65°C)

130

142

162

186

344

W

3,12

3,408

3,888

4,464

8,26

kWh/24h

Energy class

C

C

C

C

-

Insulation type

Soft PU shells

Vbu (*)

  The non-solar usable volume indicates the quantity of water (in litres) heated directly by the thermal integration coil. It 

is calculated as the volume between the upper part of the heater and the lower part of the thermal integration element 

(integration coil lower turn). The value shown in the tale refers to the coil located in the central part of the puffer. The 

position of the coil can be changed and the volume changes as a result.

Vsol (**)

  The usable solar volume indicates the quantity of water (in litres) heated directly by the solar coil (placed in the lower 

part of the heater) minus the non-solar volume (Vbu).

(***)

 

Electrical heating element (not supplied).

Содержание 7200/3F HV PLUS Series

Страница 1: ...cod Doc 0071233 rev 3 09 2017 7200 3F HV PLUS EN INSTALLATION OPERATION AND MAINTENANCE MANUAL ...

Страница 2: ... to prop erty or injury to persons or animals caused by improper in stallation adjustment maintenance or use 9 9The product must be serviced at least once a year Servicing must be arranged in advance with the R Technical Assis tance Service 9 9All servicing and repairs must be performed by a qualified heating engineer 9 9If water leaks from the storage cylinder turn off the water supply and contac...

Страница 3: ...ly water as there is a danger of freezing and over heating 0 0Do not use connections or safety devices or fittings expan sion vessels pipes insulation that are not specifically de signed and tested for use in solar water heating systems 0 0Do not allow children or infirm persons to operate the sys tem unsupervised 0 0Do not dispose of packaging material into the environment or leave it within the ...

Страница 4: ... 190 305 325 543 kg First magnesium anode Ø x length 32x700 mm Second magnesium anode Ø x length 32x400 32x700 mm Flange diameter external internal 290 220 mm Diameter length of sensor sockets 8 200 mm Sleeve for electric heating element 1 1 2 Ø Maximum operating pressure of storage cylinder 10 8 bar Maximum operating temperature 99 C Discharges according to EN 12897 2006 T 45 C am bient 20 C and ...

Страница 5: ...0 models Partially remove the cladding remove the washer and unscrew the anode holder plug in the sleeve using a spanner Insert the anode provided tighten the anode using a spanner and then put the washer back in position 7200 3F HV PLUS 2000 3000 models Before fitting the cladding unscrew the anode holder plug in the sleeve using a spanner Insert the anode provided and tighten the anode using a s...

Страница 6: ...e sure that the system is fitted with safety and con trol devices in accordance with applicable legislation and standards Make sure that the central heating circuit has been flushed out to remove all sludge and lime scale and has been vented and seal tested Make sure that a suitable water treatment system is in stalled if the quality of the supply recirculation water so demands refer to the refere...

Страница 7: ...250 1345 1455 mm D 670 760 800 820 865 mm E 600 690 730 750 795 mm F 350 350 435 410 475 mm G 240 240 280 250 190 mm H 790 790 1000 1100 1250 mm I 470 470 545 555 580 mm L 760 820 865 mm M 940 1075 1075 1085 1165 mm N 1130 1295 1290 1345 1455 mm O 1320 1610 1505 1670 1860 mm P 1510 1830 1720 1990 2265 mm Q 1810 2140 2120 2425 2700 mm Net weight with insulation 168 188 303 321 543 kg 9 9It is recom...

Страница 8: ... electricity supply ON at the mains power switch and at control panel switch if fitted 16 TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with exter nal temperatures above 0 C set the heater temperature control where available to the minimum value 9 9If the temperature to which the heater is exposed can fall below 0 C...

Отзывы: