3

GENERAL INFORMATION

GENERAL INFORMATION

 

9

Size the solar expansion tank so as to ensure complete ab-

sorption of the expansion of the fluid contained within the 

system, with reference to the prevailing regulations on the 

matter. In particular, consider fluid characteristics, consid-

erable fluctuation of service temperature and vapour that 

might be generated during solar collector stagnation stage. 

Proper size of expansion tank ensures setting off of all vol-

ume changes of the heat transfer fluid, avoiding excessive 

pressure increase. Limited pressure changes avoid reach-

ing safety valve opening pressure and the consequent fluid 

drainage.

PRECAUTIONS

The operation of any appliance that uses electrical power de-

mands that a number of fundamental safety precautions be re-

spected. In particular:

 

0

Never attempt to install the system without using suitable 

personal  protection  equipment  and without  following  all 

applicable occupational safety standards.

 

0

Do not touch the product when barefoot or wet if it has any 

electrical accessories installed in it.

 

0

Never  clean  or  service  the  storage  cylinder  without  first 

turning the mains power switch OFF to disconnect all elec-

trical accessories (if fitted) from the mains electricity supply.

 

0

Never pull, disconnect, or twist any electrical cables coming 

from the appliance even if it is disconnected from the mains 

electricity supply.

 

0

Do not expose the storage cylinder to the elements. It is not 

designed for use outdoors.

 

0

If solar plant pressure decreases, it is forbidden to top up 

with only water as there is a danger of freezing and over-

heating.

 

0

Do not use connections or safety devices or fittings (expan-

sion vessels, pipes, insulation) that are not specifically de-

signed and tested for use in solar water heating systems.

 

0

Do not allow children or infirm persons to operate the sys-

tem unsupervised.

 

0

Do not dispose of packaging material into the environment, 

or leave it within the reach of children, since it can become 

a potential hazard. Dispose of packaging material in com-

pliance with applicable legislation.

DESCRIPTION OF THE APPLIANCE

R

 

7200/3F HV PLUS

 solar tanks can be integrated into solar 

systems to produce domestic hot water. They can also be paired 

with heat pumps or boilers and heating units.

The most important technical features of these solar storage cyl-

inders are:

 

− special tank design and shape for optimum performance 

in terms of stratification, heat exchange and replenish-

ment time

 

− Water fittings are available at different heights, permit-

ting different hot water generators to be used without 

reducing the stratification effect

 

− insulation made of expanded polyurethane free from CFC 

(chlorofluorocarbons)

 

− the  use  of  three  flanges,  which  means  additional  ex-

changers can be added

IDENTIFICATION

The 

R

 

7200/3F HV PLUS

 solar heaters can be identified by:

Data plate

This lists the technical specifications and performance of the 

product.

Serial number plate

This specifies the serial number and model.

 

9

If these plates or any other means of clearly identifying 

the product are defaced, removed or lost, proper instal-

lation and servicing may be rendered difficult.

 

9

On models 2000 and 3000 the technical data plate and 

serial number plate must be applied (by the installer) af-

ter the insulation has been fitted.

Содержание 7200/3F HV PLUS Series

Страница 1: ...cod Doc 0071233 rev 3 09 2017 7200 3F HV PLUS EN INSTALLATION OPERATION AND MAINTENANCE MANUAL ...

Страница 2: ... to prop erty or injury to persons or animals caused by improper in stallation adjustment maintenance or use 9 9The product must be serviced at least once a year Servicing must be arranged in advance with the R Technical Assis tance Service 9 9All servicing and repairs must be performed by a qualified heating engineer 9 9If water leaks from the storage cylinder turn off the water supply and contac...

Страница 3: ...ly water as there is a danger of freezing and over heating 0 0Do not use connections or safety devices or fittings expan sion vessels pipes insulation that are not specifically de signed and tested for use in solar water heating systems 0 0Do not allow children or infirm persons to operate the sys tem unsupervised 0 0Do not dispose of packaging material into the environment or leave it within the ...

Страница 4: ... 190 305 325 543 kg First magnesium anode Ø x length 32x700 mm Second magnesium anode Ø x length 32x400 32x700 mm Flange diameter external internal 290 220 mm Diameter length of sensor sockets 8 200 mm Sleeve for electric heating element 1 1 2 Ø Maximum operating pressure of storage cylinder 10 8 bar Maximum operating temperature 99 C Discharges according to EN 12897 2006 T 45 C am bient 20 C and ...

Страница 5: ...0 models Partially remove the cladding remove the washer and unscrew the anode holder plug in the sleeve using a spanner Insert the anode provided tighten the anode using a spanner and then put the washer back in position 7200 3F HV PLUS 2000 3000 models Before fitting the cladding unscrew the anode holder plug in the sleeve using a spanner Insert the anode provided and tighten the anode using a s...

Страница 6: ...e sure that the system is fitted with safety and con trol devices in accordance with applicable legislation and standards Make sure that the central heating circuit has been flushed out to remove all sludge and lime scale and has been vented and seal tested Make sure that a suitable water treatment system is in stalled if the quality of the supply recirculation water so demands refer to the refere...

Страница 7: ...250 1345 1455 mm D 670 760 800 820 865 mm E 600 690 730 750 795 mm F 350 350 435 410 475 mm G 240 240 280 250 190 mm H 790 790 1000 1100 1250 mm I 470 470 545 555 580 mm L 760 820 865 mm M 940 1075 1075 1085 1165 mm N 1130 1295 1290 1345 1455 mm O 1320 1610 1505 1670 1860 mm P 1510 1830 1720 1990 2265 mm Q 1810 2140 2120 2425 2700 mm Net weight with insulation 168 188 303 321 543 kg 9 9It is recom...

Страница 8: ... electricity supply ON at the mains power switch and at control panel switch if fitted 16 TEMPORARY SHUTDOWN To reduce to the environmental impact and save energy in case of brief absences week ends short trips etc and with exter nal temperatures above 0 C set the heater temperature control where available to the minimum value 9 9If the temperature to which the heater is exposed can fall below 0 C...