8
2.5A BOILER FAULT CODES
ERROR
CODE
FAULT
DESCRIPTION OF ALARM
TYPE
E010
flame lockout/
condensate discharge blockage
fumes discharge alarm/air intake obstructed
definitive
E011
extraneous flame
transitional
E020
limit thermostat
definitive
E030
fan fault
definitive
E040
pressure transducer – load system
definitive
E041
water transducer – load system
transitional
E042
water transducer fault
definitive
E060
domestic hot water probe fault
transitional
E070
flow sensor fault
flow sensor overtemperature
flow/return sensor differential alarm
transitional
definitive
definitive
E077
water thermostat main zone or zone 1 (when enabled)
transitional
E080
return line probe fault
return line probe overtemperature
outlet/return line probe differential alarm
transitional
definitive
definitive
E084
delivery line probe fault - zone 1
transitional
E086
delivery line probe fault - main zone
transitional
E090
flue gas probe fault
flue gas probe overtemperature
transitional
definitive
E091
clean primary heat exchanger
transitional
E099
reset attempts exhausted, boiler blocked
definitive, not resettable
<0,6 bar
Low water pressure check the HTG system
>3,0 bar
High water pressure check the HTG system
COM
lost communication with boiler board
transitional
COMP
lost communication with main zone
transitional
COM1
lost communication with zone 1
transitional
FWER
FW version not compatible
definitive
OBCD
damaged clock
signalisation
OTER
OTBus configuration fault
For reset faults, except for E40-E041, call engineer.
2.6A INFO MENU
Pressing key 3 on the display screen displays a list of informa-
tion regarding the operation of the boiler listed by parameter
name and value. Passing from the display of one parameter to
the next takes place by pressing respectively the keys
and
. Pressing the key allows the selected parameter to be
displayed; pressing the key
returns you to the main screen:
Parameter
name
Scrolling message
only if parameter P1.05 = 1 Description
I0.01
SCREED HEATING HOURS
Number of hours passed with screed heater function
I0.02
CH PROBE
Boiler delivery sensor value
I0.03
RETURN PROBE
Boiler return sensor value
I0.04
DHW PROBE
Domestic hot water probe value
I0.08
EXHAUST PROBE
Flue gas probe value
I0.09
OUTDOOR TEMP PROBE
Outdoor temperature sensor instantaneous value
I0.10
FILTERED OUTDOOR TEMP
Outdoor temperature fi ltered value used in the thermoregulation algorithm for
calculating the heating setpoint
I0.11
DHW FLOW RATE
For instantaneous boiler with fl owmeter
DHW SETPOINT
Only in case of OTBus connection
I0.12
FAN SPEED
Number of turns of the fan (rpm)
I0.13
MAIN ZONE OUTLET
Main zone fl ow sensor value (when P4.12 = 1)
I0.14
ZONE 1 OUTLET
Zone 1 fl ow sensor value (when P4.13 = 1)
I0.15
EXHAUST PROBE HOURS
Number of hours the heat exchanger has been operating in “condensing mode”
I0.16
MAIN ZONE SET
Main zone delivery setpoint
I0.17
ZONE 1 SET
Zone 1 delivery setpoint (when P4.23 = 1)
I0.18
WATER PRESSURE
System pressure
I0.30
COMFORT
Domestic hot water comfort (COFF, CSTD)
I0.31
SUN ON
Special functions active for high domestic hot water temperature inputs
I0.33
PCB ID
Electronic board card identifi cation
I0.34
PCB FW
Electronic board card fmw revision
I0.35
INTERFACE FW
Interface fmw