17
INStAllAtION
2
INSTALLATION
9
Ensure that the installation and operation sites are properly
ventilated in order to disperse any gas leaks that could cau-
se flames during activities with intense heat generation and
high temperature.
9
Avoid proximity to sources of ignition in continuous opera-
tion (open flames, gas household appliances, electric sto-
ves, lit cigarettes, etc).
9
Use equipment suitable for the system refrigerant.
9
Use an electronic leak finder properly calibrated for the sy-
stem refrigerant.
0
It is forbidden to use leak finders with halogen lamps.
0
2.1
Receiving the product
R
AARIA PRO P
is supplied in a single pack, protected by a
cardboard box and by polystyrene elements.
The following material is placed inside the packaging, below the
unit
Document envelope:
—
Instruction's book for the installer and for the Technical
Service in Italian
—
Instruction's book for the installer and for the Technical
Service in English
—
Warranty/Spare parts labels.
—
energy label
—
etichetta gas refrigerante
—
contact sheet
It is also supplied as kit:
—
Condensate outlet hose.
—
4 x vibration dampers
—
5 mm hex wrench
—
2 screws to connect refrigerant connections cover
9
The Instruction book comes with the equipment and it
should be taken, read and kept carefully.
9
The document envelope must be kept in a safe place. Any
duplicate must be requested from Riello S.p.A. which reser-
ves to charge the cost.
9
2.2
Labels positioning
A
Package label
B
Transport label
B
A
A
2.3
Dimensions and weight
L
P
H
Model
1070 M 1100 M 1125 M
1125 t
1140 t
Packaging dimensions
H
mm
800
820
1130
1130
1500
L
mm
1000
1036
1050
1050
1050
P
mm
420
478
485
485
485
Weight
kg
49,0
65,0
89,0
91,0
118,0