5
GENERAl INfORMAtION
0
It is strictly forbidden to touch the coil fins, the moving par-
ts, to place any body parts between them, or to insert pointy
objects into the grilles.
0
It is forbidden to perform any technical interventions or
cleaning operations before having disconnected the devi-
ce from its electrical power supply, by setting the system's
main switch to its "OFF" position.
0
It is forbidden to modify the safety or regulation devices wi-
thout the authorisation of the manufacturer.
0
Do not pull, detach or twist the electrical wires coming out
of the unit, even when the unit is disconnected from the
power grid.
0
The packing material must not be disposed of in the sur-
rounding environment and must be kept out of children
reach, as it can be dangerous. It must be disposed of accor-
ding to the regulations in force.
0
1.3
Unit description
R
AARIA PRO P
is a heat pump outdoor unit that can be cou-
pled to indoor units of the same series for the air-conditioning
of middle-sized rooms. Designed for outdoor installation, it is
suitable for use in commercial applications.
The rotary-type compressor is controlled via DC-Inverter control
with continuous modulation from 20% to 110%, thus ensuring
high energy standards. The fan DC motor improves performance
and sound comfort. The expansion valve electronically optimises
the flow of refrigerant within the circuit.
R
chose R32 refrigerant as an alternative to low environmen-
tal impact in the conditioning range, replacing the R410A.
1.4
Safety and adjustment devices
The device safety and setting are achieved thanks to
—
compressor motor thermal protection, which is triggered in
case the current consumed by the compressor is excessive
—
gas delivery temperature sensor, which transmits the de-
tected value to the electronic board that is triggered in case
of overtemperature (110°C)
—
anti-freeze sensor, which transmits the temperature value
as detected by the heat exchanger to the electronic board
that is triggered when the heat exchanger is clogged by
frost formations
—
suction temperature sensor, which transmits the detected
value to the electronic board that is triggered in order to
adjust the flow of refrigerant gas or to stop the unit in case
of overtemperature (40°C)
—
outdoor air temperature sensor, which transmits the de-
tected value to the electronic board that is triggered in or-
der to adjust the operation of the unit indoor components
to the variation of weather conditions
9
Safety device replacement must be carried out by
R
Technical Support Service, using only original components.
Please refer to the spare parts catalogue.
0
IT IS FORbIDDEN to operate the device with faulty safety sy-
stems.
0
1.5
Identification
The unit can be identified through the technical data plate:
RIELLO Spa - Via Ing. Pilade Riello, 37045
LEGNAGO (VR) - Italy
Model
AARIA MONO 25 PLUS
Code 20127851
Max work pressure
ITEM
1PH,230V~,50Hz
T1
PARAMETER
Pdesignc Capacity (kW)
SEER
Climate class
Net weight
Power supply
Anti-electric shock
Pdesignh Capacity (kW)
SCOP
Refrigerant
Equivalent weight
R32
CO2
0.8 kg
0.54 tonnes
4.3 MPa
33.0 kg
Class I
2.6
8.5
2.5
1.5
4.6
6.7
IP24
Rated power input (kW)
Rated current (A)
Heating Capacity (kW)
3.6
GWP
675
MADE IN P.R.C.
S.N.
The product contains fluorinated greenhouse gases
and its functioning relies upon such gases.
0010590475
Manufacture date:
technical data plate
Contains the device's technical and performance data.
9
The tampering, removal, or absence of the identification
plates will not allow the product to be properly identified by
its serial number.