2-25
Confidential
Print Unable
05
Turn the power off
and then back on
again.
Detected the fuser unit
temperature error.
0501
0502
0503
0504
0505
0506
0508
050A
050B
050C
Print Unable
09
Turn the power off
and then back on
again.
Detected irregular power supply
for more than 100 times.
0900
Print Unable
0A
Turn the power off
and then back on
again.
Detected a fan failure.
0A02
Print Unable
0B
Turn the power off
and then back on
again.
An error occurred in the high-
voltage power supply PCB
ASSY while operating.
0B01
An error occurred in the high-
voltage power supply PCB
ASSY when the machine was in
the ready state.
0B02
Print Unable
3A
Turn the power off
and then back on
again.
A communication error occurred
between the controller and
engine in main PCB.
3A00
Print Unable
A7
Turn the power off
and then back on
again.
Color parameter in the ROM
does not match the CIS.
A700
Print Unable
A9
Turn the power off
and then back on
again.
A scanning error occurred while
processing the scanned image.
A900
Print Unable
D1
Turn the power off
and then back on
again.
An error occurred while
initializing the modem.
D100
Print Unable
E0
Turn the power off
and then back on
again.
An error occurred in the ROM
check sum.
E000
Print Unable
E1
Turn the power off
and then back on
again.
Program error
E100
Error message
Description
Error
codes
Refer
to:
Initial display
Scroll
Содержание SP 230SFNw
Страница 29: ...2 8 Confidential 2 2 2 Scanner part Fig 2 4 Document feed path...
Страница 120: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton...
Страница 177: ...3 59 Confidential 8 21 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 51 Hook Filter Air duct...
Страница 226: ...5 21 Confidential Print adjustment test pattern Fig 5 5...
Страница 234: ...5 29 Confidential Print pattern Fig 5 9 W 100 K 1 K 100 Total Lattice K 5...
Страница 239: ...5 34 Confidential Test pattern Fig 5 12...