5-18
Confidential
Adjust upper-end print position
<Function>
In the event that the upper-end print start position deviates, use this function to adjust the
position up and down. Adjustable range is -50 to 50 (1 unit = 0.084 mm = 300 dpi).
(Shifted down when the value is negative)
<Operating Procedure>
(1) Press the [4], and then the [5] in the initial state of maintenance mode. For models
without keypad, press the [
▲
] or [
▼
] to display “MAINTENANCE 45” on the LCD and
press the [OK]. “USBNo.” is displayed on the LCD.
(2) Press the [
▲
] or [
▼
] to display “Y Adjust” on the LCD, and press the [SET] or [OK].
“YAdjust T1” is displayed on the LCD.
(3) Refer to <Adjustment option table> in the table below, press the [
▲
] or [
▼
] to select from
the adjustment options, and press the [SET] or [OK]. “YAdj. **= 0*” is displayed on the
LCD. (Selected option is shown for **.)
(4) To shift the writing start position down, press the [
▼
] to decrease the value. To shift the
position up, press the [
▲
] to increase the value.
(5) Press the [SET] or [OK] after adjusting the value. “Accepted” is displayed on the LCD.
(6) Press the [X] or [Stop], and the machine returns to the initial state of maintenance mode.
<Adjustment option table>
*1
Adjusts first side print start position of all tray (paper tray). Value of Y Adjust TRAY and Y
Adjust DX is added to each tray adjustment value.
For example, when printing from paper tray, it adjusts as “Y Adjust T1 value” + “Y Adjust
TRAY value” or “Y Adjust DXT1 value” + “Y Adjust DX value” and print. Besides, when the
added value is over than the adjustable range (-50 to 50), adjusted value will be for
minimum -50 and maximum 50 and does not become out of adjustable range.
*2
Adjusts second side print start position of all tray (paper tray). Value of Y Adjust TRAY is
added to each tray adjustment value.
For example, when printing from paper tray, it adjusts as “Y Adjust T1 value” + “Y Adjust
TRAY value” and print. Besides, when the added value is over than the adjustable range
(-50 to 50), adjusted value will be for minimum -50 and maximum 50 and does not become
out of adjustable range.
Single-side printing
Duplex printing
Adjustment option
LCD
Adjustment option
LCD
Paper tray first side
Y Adjust T1
Paper tray second side
Y Adjust T1
*1
Y Adjust TRAY
*2
Y Adjust TRAY
N/A (disabled)
Y Adjust DX
*1
Y Adjust DX
N/A (disabled)
Y Adjust DXT1
Paper tray first side
Y Adjust DXT1
Содержание SP 230SFNw
Страница 29: ...2 8 Confidential 2 2 2 Scanner part Fig 2 4 Document feed path...
Страница 120: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton...
Страница 177: ...3 59 Confidential 8 21 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 51 Hook Filter Air duct...
Страница 226: ...5 21 Confidential Print adjustment test pattern Fig 5 5...
Страница 234: ...5 29 Confidential Print pattern Fig 5 9 W 100 K 1 K 100 Total Lattice K 5...
Страница 239: ...5 34 Confidential Test pattern Fig 5 12...