![Ricoh SP 230SFNw Скачать руководство пользователя страница 151](http://html1.mh-extra.com/html/ricoh/sp-230sfnw/sp-230sfnw_service-manual_1455349151.webp)
3-33
Confidential
(4) Remove the Screw cup M3x8 (black) screw to remove the FB ground harness and the
Panel ground harness. Disconnect the Document scanner motor harness from the Main
PCB ASSY.
(5) Remove the Screw cup M3x8 (black) screw to remove the ADF ground harness.
Disconnect the ADF sensor harness and the ADF motor harness from the Main PCB
ASSY.
(6) Disconnect the CIS flat cable and the Panel flat cable from the Main PCB ASSY.
Fig. 3-19
Harness routing: Refer to
,
.
Note:
• After disconnecting flat cables, check that each cable is not damaged at its end or
short-circuited.
• When connecting flat cables, do not insert them at an angle. After insertion, check
that the cables are not at an angle.
ADF ground harness
Screw cup M3x8 (black)
Panel ground harness
Main PCB ASSY
Screw cup M3x8 (black)
Main PCB ASSY
CIS flat cable
ADF sensor harness
Panel flat cable
ADF motor harness
Document scanner motor harness
FB ground harness
Содержание SP 230SFNw
Страница 29: ...2 8 Confidential 2 2 2 Scanner part Fig 2 4 Document feed path...
Страница 120: ...3 2 Confidential 2 PACKING Fig 3 1 Option carton Carton Polystyrene pad ASSY Spacer carton...
Страница 177: ...3 59 Confidential 8 21 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 51 Hook Filter Air duct...
Страница 226: ...5 21 Confidential Print adjustment test pattern Fig 5 5...
Страница 234: ...5 29 Confidential Print pattern Fig 5 9 W 100 K 1 K 100 Total Lattice K 5...
Страница 239: ...5 34 Confidential Test pattern Fig 5 12...