3-30
Confidential
8.9 Side cover L / Speaker harness ASSY
(1) Remove the Taptite bind B M4x12 screw.
(2) Release each Hook A, B, and the Hook C on the Side cover L in order of the arrow A to C,
and remove the Side cover L.
(3) Disconnect the Speaker harness ASSY from the Main PCB ASSY.
Fig. 3-16
Harness routing: Refer to
.
Note:
• When removing the Side cover L, DO NOT pull the Side cover L strongly because
it is connected to the Speaker harness ASSY.
Hooks A
Hooks B
Side cover L
Hook C
C
B
A
Taptite bind B
M4x12
Main PCB ASSY
Speaker harness ASSY
Speaker
harness
ASSY