3-29
Confidential
8.8 Inner chute ASSY
(1) Pull down the Green envelope levers on both sides of the Fuser unit.
(2) Remove the two Taptite bind B M4x12 screws, and remove the Inner chute ASSY.
Fig. 3-15
Assembling Note:
• When attaching the Inner chute ASSY, engage the Hooks on the Inner chute ASSY
with the Positioning holes on the Joint cover ASSY.
• After assembling the Inner chute ASSY, pull up the Green envelope levers on both
sides of the Fuser unit.
Fuser unit
Hooks
Green
envelope lever
Taptite bind B
M4x12
Inner chute ASSY
Green envelope lever
Fuser unit