BIT SWITCHES
14 June, 2002
5-24
5.2 BIT
SWITCHES
!
WARNING
Do not adjust bit switches described as "Not used", as this may cause the machine to
malfunction or to operate in a manner that is unacceptable under local regulations. Such bits
are only for use in other areas, such as Japan.
NOTE:
This manual does not list default settings for bit switches. Refer to the
System Parameter List.
The switches that have been changed from the previous model (Kaiser1)
are shaded.
5.2.1 SYSTEM SWITCHES
System Switch 00
No FUNCTION
COMMENTS
0-1 RAM
Reset
Bit 1 Bit 0 Reset Level
0 0 No reset
0 1 Reset Level 2
1 0 Reset Level 3
1 1 Not used
Reset Level 3:
Erases all image data files
stored in the SAF memory and communication
files (e.g. substitute RX files). This is the
recommended setting when the SAF requires
clearing.
Reset Level 2:
This level erases the following
items in addition to those erased by Reset
Level 3: own telephone number, bit switches
(excluding country code), RTI/TTI/CSI, report
data, programmed telephone numbers
(Quick/Speed/Groups, service station, etc.),
NCU parameters. The NCU country code is
also set to the same as the bit switch country
code (System Bit Switch 0F).
After erasing, the machine automatically
changes these two bits back to 0.
No reset:
Normal operation
Cross-reference
RAM Reset Level 1 (Factory reset):
Change the RAM address data from
400005(H) to FF(H), then turn the machine off
and on. In addition to those items erased by
Reset Level 2, the clock, country code (the
default country code is USA), scan margin
settings, and print registration settings are
erased.