14 June, 2002
SERVICE RAM ADDRESSES
5-91
Service
Tables
4000F0(H) - User parameter switch 00
Bit 0: Stamp home position 0: Disabled, 1: Enabled
Bits 1 and 2: Scanning contrast home position
Bit
2 1 Setting
0 0 Normal
0 1 Lighten
1 0 Darken
Bit 3: Do not adjust
Bits 4 and 5: Scanning resolution home position
Bit
5 4 Setting
0 0 Standard
0 1 Detail
1 0 Super
Fine
1 1 Ex.
Super
Fine
Bit 6: Transmission mode home position 0: Memory TX, 1: Immediate TX
Bit 7: Half tone mode home position 0: OFF, 1: ON
4000F1(H) - User parameter switch 01
Bits 0 to 5: Not used
Bit 6: The alarm after communication is finished
0: OFF, 1: ON
Bit 7: Settings return to home position after transmission 0: Disabled, 1: Enabled
4000F2(H) - User parameter switch 02
Bit 0: Forwarding mark printing on forwarded messages 0: Disabled, 1: Enabled
Bit 1: Center mark printing on received copies
0: Disabled, 1: Enabled
Bit 2: Reception time printing
0: Disabled, 1: Enabled
Bit 3: TSI included in transmitted messages
0: Disabled, 1: Enabled
Bit 4: Checkered mark printing
0: Disabled, 1: Enabled
Bit 5: CIL printing (G4)
0: Disabled, 1: Enabled
Bit 6: TID printing (G4)
0: Disabled, 1: Enabled
Bit 7: Not used
4000F3(H) - User parameter switch 03
(Automatic report printout)
Bit 0: Transmission result report (memory transmissions) 0: Off, 1: On
Bit 1: Not used
Bit 2: Memory storage report
0: Off, 1: On
Bit 3: Polling reserve report (polling reception)
0: Off, 1: On
Bit 4: Polling result report (polling reception)
0: Off, 1: On
Bit 5: Transmission result report (immediate transmissions)
0: Off, 1: On
Bit 6: Polling clear report
0: Off, 1: On
Bit 7: Journal
0: Off, 1: On