ADF/SCANNER SECTIONS
14 June, 2002
3-4
3.2 ADF/SCANNER
SECTIONS
3.2.1 REPLACING THE PICK-UP ROLLER (PART OF THE ADF
MAINTENANCE KIT)
1. Open the ADF upper cover [A].
2. Remove the pick-up roller unit [B].
NOTE:
Slide the unit toward the rear (toward the spring-loaded end). The front
bushings will detach and the unit can then be removed.
NOTE:
If you install all parts in the ADF maintenance kit at the same time, be sure
to reset the PM counter (ADF).
3.2.2 REPLACING THE FEED ROLLER (PART OF THE ADF
MAINTENANCE KIT)
First, do the first two steps of the pick-up roller replacement procedure above.
1. Release the pick-up roller stopper [C] and pull the shaft toward the end with the
E-clip [D]. This will allow the pick-up roller to be removed.
2. Remove the three E-clips from the feed roller [E].
3. Release the roller clutch stoppers [F], pull out the shaft [G], and remove the
feed roller.
NOTE:
If you install all parts in the ADF maintenance kit at the same time, be sure
to reset the PM counter (ADF).
H310R001.WMF
H310R025.WMF
[A]
[B]
[C]
[D]
[E]
[F]
[G]