9 Trans.: Mode4
10 Trans.: Mode5
11 Film: Mode1
12 Film: Mode2
13 Film: Mode3
14 Film: Mode4
15 Film: Mode5
16 Plain:Ltemp
[60 to 80 /120/5
o
C]
1934
LTemp:HotRol
Lower Limit Temperature: Hot Roller
This SP sets the minimum difference in temperature allowed between the actual temperature
and the target temperature of the hot roller.
Important:
• Modes "1" to "5" below refer to the paper and thickness settings selected in User Tools
(see "Paper Thickness Default Selection" in this section). In order for this SP to operate,
SP9952 1 must be at "0" (default) so that the machine can acquire temperature readings
(feedback) from the pressure roller thermistors.
• The default setting of SP9952 should never be adjusted in the field.
1 Plain: Mode1
[0 to 50/20/5]
2 Plain: Mode2
[0 to 50/15/5]
3 Plain: Mode3
[0 to 50/25/5]
4 Plain: Mode4
[0 to 50/20/5]
5 Plain: Mode5
6 Trans.: Mode1
7 Trans.: Mode2
8 Trans.: Mode3
9 Trans.: Mode4
10 Trans.: Mode5
5. Service Tables
264
5
Содержание Neptune-P1
Страница 1: ...Neptune P1 Machine Code G180 SERVICE MANUAL June 2007 Subject to change...
Страница 13: ...Folder D889 452 Manual Feeder D333 453 Paper Cassette B853 454 Main Machine Configuration 455 12...
Страница 103: ...1 Installation 102 1...
Страница 111: ...Fusing Gears 1 Fusing Gears Barrieta S552R Apply to the surface of the rim 2 Preventive Maintenance 110 2...
Страница 114: ...Rear Cover 1 Rear cover x 2 A 2 Controller cover B x 1 Paper Exit Unit Common Procedures 113 3...
Страница 142: ...RF Exit Sensor 1 Open the drawer of the roll feeder 2 Plate A x 2 3 RF exit sensor B x 1 x 1 Paper Feed 141 3...
Страница 170: ...5 Remove the PSU A x1 x10 x all Controller Board 1 Remove A Rear cover x2 B Controller cover x1 Boards 169 3...
Страница 177: ...3 Remove the SFDB A x 2 x 2 standoffs x 2 3 Replacement and Adjustment 176 3...
Страница 180: ...4 Remove the cooling fan D x3 x1 Others 179 3...
Страница 402: ...Toner End Recovery Flow Chart Development 401 6...
Страница 449: ...6 Details 448 6...
Страница 457: ...MEMO 456...