Preparation
B286/B289 1-2
SM
9. Put the machine on a strong and level surface.
!
The floor must be able to support a load of more than 2.94 kPa (300 kgf/m2.
10. Do not install the machine in an area where there are frequent strong vibrations.
1.1.2 MINIMUM SPACE REQUIREMENTS
1. Front: 1000 mm (40”)
2. Back: 600 mm (23”)
3. Right: 600 mm (23”)
4. Left: 600 mm (23”)
1.1.3 MACHINE LEVEL
1. Front to back: Not more than 5 mm from level
2. Right to left: Not more than 0.15/1000 mm from level.
1.1.4 POWER SOURCE
!
This machine is provided with a circuit breaker that cuts the power supply to the
main machine in case of a current overload or short circuit. The machine must be
installed in a building where circuit breakers (and equivalent devices) can operate
properly.
1. Input Voltage Level:
!
120V, 60 Hz, 15 A or more
Содержание B286
Страница 1: ...B286 B289 SERVICE MANUAL 003165MIU...
Страница 2: ......
Страница 3: ...B286 B289 SERVICE MANUAL...
Страница 4: ......
Страница 5: ...B286 B289 SERVICE MANUAL 003165MIU...
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 27: ......
Страница 29: ......
Страница 34: ......
Страница 35: ...INSTALLATION...
Страница 36: ......
Страница 117: ...PREVENTIVE MAINTENANCE...
Страница 118: ......
Страница 127: ...REPLACEMENT AND ADJUSTMENT...
Страница 128: ......
Страница 186: ...Boards B286 B289 3 58 SM 9 Remove the shield cover A x12 10 Remove A MCU x4 x1 B IPU x4...
Страница 198: ...Others B286 B289 3 70 SM 4 Remove the cooling fan D x 1 x 3...
Страница 216: ......
Страница 217: ...TROUBLESHOOTING...
Страница 218: ......
Страница 269: ...SERVICE TABLES...
Страница 270: ......
Страница 507: ...DETAILS...
Страница 508: ......
Страница 511: ...Overview SM 6 3 B286 B289 Details 6 1 2 MECHANICAL COMPONENT LAYOUT...
Страница 513: ...Overview SM 6 5 B286 B289 Details 6 1 3 DRIVE LAYOUT 1 Scanner Motor 2 Drum Motor 3 Main Motor 4 Fusing Motor...
Страница 526: ...Image Processing B286 B289 6 18 SM Text Mode...
Страница 529: ...Image Processing SM 6 21 B286 B289 Details Patched Original Mode...
Страница 530: ...Image Processing B286 B289 6 22 SM Generation Mode...
Страница 552: ...Development B286 B289 6 44 SM Toner End Recovery Flow Chart...
Страница 553: ...Paper Feed and Registration SM 6 45 B286 B289 Details 6 7 PAPER FEED AND REGISTRATION 6 7 1 OVERVIEW Layout Diagrams...
Страница 585: ...Fusing Unit SM 6 77 B286 B289 Details In the table below PR is the Pressure Roller and HR is the Hot Roller...
Страница 613: ...SPECIFICATIONS...
Страница 614: ......