4747 CIS Hard Error Flag
DFU
This SP displays the flags of errors that occur during the CIS communication
check done immediately after power on.
b0 Serial output port abnormal. Signal at HIGH level became “1.”
b1 Read failure. Failed to read CIS unit version information.
b2
Write failure. A value was written to the CIS register (AGC_CONT) but it
could not be read.
4762 CIS Gain Adjustment Normally
DFU
These SP’s display the gain data of the analog ASIC (EVEN or ODD) from the
CIS after the white level adjustment done immediately after power on. The white
level adjustment sets the peak value (shading data peak) for each channel at
240±2 digits.
1 CIS1 : GE(ven)
[0 to 255/0/1]
2 CIS1 : GO(dd)
3 CIS2 : GE(ven)
4 CIS2 : GO(dd)
5 CIS3 : GE(ven)
6 CIS3 : GO(dd)
7 CIS4 : GE(ven)
8 CIS4 : GO(dd)
9 CIS5 : GE(ven)
10 CIS5 : GO(dd)
Содержание B286
Страница 1: ...B286 B289 SERVICE MANUAL 003165MIU...
Страница 2: ......
Страница 3: ...B286 B289 SERVICE MANUAL...
Страница 4: ......
Страница 5: ...B286 B289 SERVICE MANUAL 003165MIU...
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 27: ......
Страница 29: ......
Страница 34: ......
Страница 35: ...INSTALLATION...
Страница 36: ......
Страница 117: ...PREVENTIVE MAINTENANCE...
Страница 118: ......
Страница 127: ...REPLACEMENT AND ADJUSTMENT...
Страница 128: ......
Страница 186: ...Boards B286 B289 3 58 SM 9 Remove the shield cover A x12 10 Remove A MCU x4 x1 B IPU x4...
Страница 198: ...Others B286 B289 3 70 SM 4 Remove the cooling fan D x 1 x 3...
Страница 216: ......
Страница 217: ...TROUBLESHOOTING...
Страница 218: ......
Страница 269: ...SERVICE TABLES...
Страница 270: ......
Страница 507: ...DETAILS...
Страница 508: ......
Страница 511: ...Overview SM 6 3 B286 B289 Details 6 1 2 MECHANICAL COMPONENT LAYOUT...
Страница 513: ...Overview SM 6 5 B286 B289 Details 6 1 3 DRIVE LAYOUT 1 Scanner Motor 2 Drum Motor 3 Main Motor 4 Fusing Motor...
Страница 526: ...Image Processing B286 B289 6 18 SM Text Mode...
Страница 529: ...Image Processing SM 6 21 B286 B289 Details Patched Original Mode...
Страница 530: ...Image Processing B286 B289 6 22 SM Generation Mode...
Страница 552: ...Development B286 B289 6 44 SM Toner End Recovery Flow Chart...
Страница 553: ...Paper Feed and Registration SM 6 45 B286 B289 Details 6 7 PAPER FEED AND REGISTRATION 6 7 1 OVERVIEW Layout Diagrams...
Страница 585: ...Fusing Unit SM 6 77 B286 B289 Details In the table below PR is the Pressure Roller and HR is the Hot Roller...
Страница 613: ...SPECIFICATIONS...
Страница 614: ......