5.2 Calibration Menu
See the following information for standard calibration procedure.
Figure 5-2. Calibration Menu
5.2.1 Standard Calibration
See the following information for standard calibration procedure.
Use the following steps to calibrate the MSI-4260M using the standard calibration procedure.
1. Remove the hex seal screw from the MSI-4260M using the steps from
and
displays.
2. Press
,
displays.
3. Select the weight unit (
) then press
,
displays.
4. Press
,
displays.
5. Press
when the scale becomes motionless, a blinking
displays.
6. If the scale is in range
displays then
displays.
7. Load the scale with a test weight (for a single span point calibration, a test weight of more than 20% of capacity or
more is recommended).
8. Press
. The current capacity flashes on the display. If loading the scale with the capacity weight, skip to
.
9. Press
if using a calibration weight other than capacity. The displays far left digit blinks indicating a number
should be entered.
10. Press
to scroll the numbers and
to enter each digit.
Example: Enter 2500 lb on a 5000 lb capacity scale.
Press
two times for the leftmost blinking digit, press
to save that digit selection.
Press
five times for the next blinking digit, press
to save that digit selection.
Press
to save that digit selection.
Press
to save the next digit selection.
displays.
11. Press
to save the weight entry. If the cal value is within limits,
is briefly displayed then
.
12. Press
if more cal points are desired or
if a single point cal is needed.
Menu
Parameter
Description
Weight Units – Toggle units between pounds and kilograms
Standard Menu – Selections:
,
,
,
)
Auto Zero Maintenance – Allows the scale to adjust the zero reading to the center-of-zero, which is defined as the
weight reading within 1/4 d of zero; Continuously adjusts zero to maintain the center-of-zero
Selections: On, Off
Zero Power Up – Selections: On, Off
Weigh Filter – Allows the scale to adjust to situations where there may be movement
Selections: On, Off
Table 5-1. Calibration Menu Parameters