2.3 Batteries
The MSI-4260M is powered by six (6) D cell 1.5 V alkaline batteries. The operating battery life is up to 1000 hours depending on
the following factors:
• The brightness of the LCD display backlight
• The amount of RF activity
• The age and condition of the batteries
In order to conserve battery life, the MSI-4260M includes the following features.
•
Automatic Power Off Mode
– Senses no activity after the set amount of minutes and turns the scale off
•
Automatic Sleep Mode
– Dims the display after a set amount of minutes of no scale activity
Do not store the MSI-4260M with the batteries inside. Remove the batteries if it will not be used for more than two weeks.
Replace batteries once the battery annunciator is flashing.
2.3.1 Battery Replacement
1. Turn the MSI-4260M off.
2. Unscrew battery caps.
3. Slide battery tubes from the MSI-4260M.
4. Remove batteries from tubes.
5. Install new batteries with plus side up.
6. Reinstall battery tubes.
Figure 2-2. Battery Replacement
Periodically, inspect O-rings and threads to maintain a tight seat of the battery tubes.