4.2.3 Total
Set the total parameter to
for the MSI-4260M
or
for the F2 key on a connected RF Rugged Remote
Control or RF remote display.
The total mode must be programmed from the Setup Menu before
will function (
).
4.2.4 View Total
activates the total weight display followed by the number of samples. Press
to clear with total weight
displayed.
4.2.5 Net/Gross
Switches the display between net and gross modes. Net weight is defined as gross weight minus a tare weight.
To switch between net mode and gross mode, press
configured to NET/GROSS. This only works if a tare value
has been established.
The operator can switch back to gross from net without clearing the tare value. Only clearing or setting a new tare changes the
tare value held before switching into gross mode.
OIML Legal for Trade units only:
The
or RF remote device
F-KEY
configured to Net/Gross is a temporary action
only. The gross weight displays for 2 seconds then the display returns to the net mode. The only way to return to permanent
gross readings is to clear the tare (
).
4.2.6 Peak Hold
Peak hold only updates the display when a higher peak weight reading is established.
The peak hold function uses a high speed mode of the A/D converter allowing it to capture transient weights at a far higher rate
than typical scales. Peak hold is cleared and re-enabled with the
or RF remote device
F-KEY
.
Peak hold is not available on NTEP or OIML Legal for Trade certified scales.
4.2.7 Unit
Unit can be changed in two ways:
• Program a user function key to units
• Change the units with the setup menu
Unit switching is not available on OIML certified Legal for Trade scales.
4.2.8 Print
If a print option is installed this menu choice appears. The setup of the print function is covered in the print RF menu.
4.3 Auto-Off
The Auto-Off feature prolongs the battery life by powering off the unit when not in use. When a button is pressed or the detected
load is in motion exceeding 10 d, the time limit is reset. When disabled, the unit remains on and only turns off when the
is pressed or the batteries run out.
Use the following steps to set the Auto-Off function:
1. Press and hold
and
.
displays.
2. Press
to scroll to
.
3. Press
. The current
time displays.
4. Press
to scroll through the available times.
5. Press
when the desired time displays.
displays.
6. Press
to exit setup and store the settings.
Press
at any time to cancel the procedure.
Note