Configuration
29
TIME
TIMEFMT
TIMESEP
Allows selection of time format and separator character. See Level 3 submenu parameter
descriptions.
Use the
TIME/DATE
softkey or the ST serial command to set the time. See Section 9.0 on
page 67 for information about using the serial commands.
DECFMT
DOT
COMMA
Specifies whether decimal numbers are displayed using a period (DOT) or comma as the
decimal symbol.
DSPRATE
1
1–80
Display update rate. Specifies the display update rate, in the number of 100-millisecond
intervals between updates. The default value, 1, provides about 10 updates per second.
The maximum value updates the display every 8 seconds.
CONSNUM
0
0–9999999
Consecutive numbering. Allows sequential numbering for print operations. The consecutive
number value is incremented following each print operation that includes <CN> in the ticket
format. When the consecutive number is reset, it is reset to the value specified on the
CONSTUP parameter.
CONSTUP
0
0–9999999
Specifies the consecutive number start-up value used when the consecutive number is
reset by sending the KCLRCN serial command or a CLRCN digital input. Value specified
must be in the range 0–9 999 999.
UID
0
unit-ID
Specifies the unit identification number. Value specified can be any alphanumeric value, up
to eight characters.
TRUCK
OFF
MODE1
MODE2
MODE3
MODE4
MODE5
MODE6
Specifies the truck mode used. If selected, the indicator switches from normal mode to the
selected truck mode. See Section 7.0 on page 47 for more information about using the
truck modes.
MODE1: Auto clear ID, keyed tares, value swapping
MODE2: Auto clear ID, no keyed tares, value swapping
MODE3: Stored ID, keyed tares, value swapping
MODE4: Stored ID, no keyed tares, value swapping
MODE5: Stored ID, keyed tares, no value swapping
MODE6: Stored ID, no keyed tares, no value swapping
CFGPWD
0
0–9999999
Configuration password. Specify a non-zero value to restrict access to all configuration
menus.
SPPWD
0
0–9999999
Setpoint password. Specify a non-zero value to restrict access to the setpoint menu.
The SPPWD is also shared by, and can be used to protect, the truck register. If a non-zero
setpoint password is specified, the password must be entered before deleting any entries
from the truck register.
SOFTKEYS
<blank>
Time/Date
Display Tare
Display Accum
Display ROC
Setpoint
Batch Start
Batch Stop
Batch Pause
Batch Reset
Weigh In
Weigh Out
Truck Regs
Unit ID
Select Scale
F1–F10
Use the
Add
and
Remove
softkeys to select softkeys to be displayed in weighing mode.
FEATURE Menu
Parameter
Choices
Description
Table 3-6. FEATURE Menu Parameters (Continued)