24
920i
Installation Manual
Secondary Units (SECNDR) and Tertiary Units (TERTIA) Parameters
DECPNT
888888.8
8888888
8888880
8888800
8.888888
88.88888
888.8888
8888.888
88888.88
Decimal point location. Determines the location of the decimal point or dummy zeros in the
secondary or tertiary units display.
DSPDIV
5D
1D
2D
Display divisions. Selects the value of minimum division size of the displayed weight for
secondary or tertiary units display.
UNITS
KG
G
OZ
TN
T
GN
TROYOZ
TROYLB
LT
CUSTOM
NONE
LB
Specifies secondary or tertiary units for displayed and printed weight. Values are:
LB=pound; KG=kilogram; G=gram; OZ=ounce; TN=short ton; T=metric ton; GN=grain;
TROYOZ=troy ounce; TROYLB=troy pound; LT=long ton.
MULT
0.453592
0.000001–
9999999
Multiplier. Specifies the conversion factor by which the primary units are multiplied by to
obtain the secondary or tertiary units. The default is 0.453592, which is the conversion
factor for changing pounds to kilograms. See Section 10.9 on page 92 for a list of
multipliers.
To shift between primary, secondary, and tertiary units, press the UNITS key.
Rate of Change (ROC) Units Parameters
DECPNT
8888888
8888880
8888800
8.888888
88.88888
888.8888
8888.888
88888.88
888888.8
Decimal point location. Determines the location of the decimal point or dummy zeros in the
display.
DSPDIV
1D
2D
5D
Display divisions. Selects the minimum division size for the ROC units displayed weight.
MULT
1.0
0.000001–
9999999
Multiplier. Specifies the conversion factor by which the primary units are multiplied by to
obtain the displayed rate of change units.
UNITS
SEC
MIN
HOUR
Rate-of-change units.
INTERVL
100
1–65535
Update interval. Specifies the number of A/D updates over which the rate-of-change is
calculated.
SCALES Menu, FORMAT Submenu
Parameter
Choices
Description
Table 3-3. SCALES Menu, FORMAT Submenu Parameters (Continued)