Configuration
27
Level 3 Submenus
Port 1–Port 4
BAUD
9600
19200
28800
38400
57600
115200
300
600
1200
2400
4800
Baud rate. Selects the transmission speed for the port.
NOTE: The maximum baud rate for ports on serial expansion cards (port number greater than 4)
is 19200.
BITS
8NONE
7EVEN
7ODD
Selects number of data bits and parity of data transmitted or received by the port.
TERMIN
CR/LF
CR
Termination character. Selects termination character for data sent from the port.
EOLDLY
0
0–255
End-of-line delay. Sets the delay period, in 0.1-second intervals, from when a formatted line is
terminated to the beginning of the next formatted serial output. Value specified must be in the
range 0-255, in tenths of a second (10 = 1 second).
HANDSHK
OFF
XONOFF
HRDWAR
Specifies whether XON/XOFF flow control characters or hardware handshaking is used.
Hardware handshaking is available only on Port 2.
ADDRESS
0
0–25
Specifies the decimal indicator address for RS-485 connections. RS-232 communications is
disabled if an address other than zero is specified for this parameter. RS-485 addresses must be
in the range 01–255.
BUS
OFF
ON
Specifies whether the port sends the data stream to a network bus. Specify ON only if the
DeviceNet, Remote I/O, or Profibus option is installed.
INPUT
CMD
PROGIN
KEYBD
SCALE
Specifies whether the port receives remote command input, programmable input, remote
keyboard input, or scale input.
KEYBD is available only on Port 2; SCALE is available only on Ports 3 and 4.
NOTE:
The keyboard interface is not hot-pluggable. Power-off the
920i
before plugging
the keyboard cable into the Port 2 connector
STREAM
OFF
LFT
INDUST
Specifies whether data is streamed from the port.
SERIAL Menu
Parameter
Choices
Description
Table 3-5. Serial Menu Parameters (Continued)