background image

Page 

9

 / 

19

 

 

children. 

 

Do not allow children to operate this product. It is not a toy. 

 

Cleaning and user maintenance shall not be made by children. 

 

When the product is not in use or before performing cleaning, turn it off, disconnect from 
the power source. 

 

Use attachments/accessories specified by the manufacturer. 

 

Do not use in the presence of flammable liquids, gases or dusts. 

 

Never leave the product running unattended. 

 

Perform service maintenance by qualified personnel only. 

 

3.2- Additional safety rules for submersible water pump 
 

 

Make sure electrical connection is made within dry area and protected from flooding. 

 

Maintain labels and rating plate through the life of service. 

 

Before cleaning or changing accessories, turn it off, disconnect the power source. 

 

Never run an overheated pump. If your pump is overheat, turn off immediately, and allow 
cooling down. 

 

Never use a pump in a flammable, explosive or corrosive environment. 

 

3.3- Special warnings when using this product 
 

 

The pump is suitable for clean water only, not for domestic sewage or water containing solid 
particles or corrosive/flammable liquid. 

 

Do not use the pump when someone or pet is in the water. 

 

The power source must be earthed. 

 

The pump must be connected to residual-current circuit breaker (RCCB) with rated leakage 
current of no more than 30 mA. 

 

The pump can be connected to shock-proof plug by professional electrician.  

 

All power plug and extension cable used with this equipment must be of suitable waterproof 
rating. 

 

Leakage of lubriant oil may cause contamination to the water. 
 
 

IV. GETTING STARTED

 

 

4.1- Unpacking 

 

 

Remove the product from packaging 

 

Check if the product and accessories (if any) are intact. 

 

4.2- Content 
 

 

1 water pump body 

 

1 water discharge pipe 

 

1 Instruction manual 

 
4.3- Assembly  
 

Connecting Water Discharge Pipe 

 

Connecting the water discharge pipe to the outlet connector (body) by turning the pipe 
connector knob. Make sure the provided gasket is inserted. 

Содержание 511736

Страница 1: ...R PUMP User and maintenance manual Original instructions IT POMPA AD ACQUA SOMMERSA AUTOMATICA Manuale di istruzione e di manutenzione Traduzioni delle istruzioni originali R f Art Nr PRPVF500AUTO 511...

Страница 2: ...perating this appliance Incorrect operation may cause injury and or damages Please keep this manual for future reference Note Non contractual information and photos which may be changed without prior...

Страница 3: ...instructions pour pouvoir s y reporter ult rieurement Conserver ce manuel port e de main pour toute r f rence ult rieure Laisser le manuel avec le produit par ex lors de son utilisation lors de son p...

Страница 4: ...ion Ne faites jamais fonctionner une pompe surchauff e Si votre pompe surchauffe teignez la imm diatement et laissez la refroidir N utilisez jamais une pompe dans un environnement inflammable explosif...

Страница 5: ...Usage destin La pompe est submersible et destin e un usage domestique Elle peut tre utilis e pour vacuer l eau des locaux inond s ou pour pomper l eau des puits ou des caves Elle n est pas destin e d...

Страница 6: ...ous que tous les joints sont solidement connect s N immergez pas la pompe une profondeur sup rieure 7 m tres ce qui pourrait endommager le produit Ne laissez pas la pompe fonctionner sans surveillance...

Страница 7: ...laissez la refroidir avant de red marrer Turbine bloqu e Supprimer le blocage et red marrer la pompe La pompe d marre et s arr te fr quemment Fuite ou colmatage interne Remplacer le tuyau et les join...

Страница 8: ...it later whenever any questions arise Always be sure to include this manual when selling lending or otherwise transferring the ownership of this product Symbols Explanation of symbols appearing on th...

Страница 9: ...a pump in a flammable explosive or corrosive environment 3 3 Special warnings when using this product The pump is suitable for clean water only not for domestic sewage or water containing solid partic...

Страница 10: ...rcial artisanal and or industrial uses The pump is designed to work in clear water with suspended particle size not more than 5mm The pump is designed to work in water temperature not exceeding 35 C T...

Страница 11: ...E WARNING Before any intervention on product disconnect from power source Reminder In order to maintain the machine in good working condition carry out regular maintenance of the machine after each us...

Страница 12: ...ipe hose and joints clean blockage The pump runs but no or little water flow Insufficient water lower than impeller Change working location or position before restart the pump Pipe or hose bent or dam...

Страница 13: ...futura Tenere questo manuale a portata di mano in modo da poter far riferimento in un secondo momento in caso di dubbi Assicurasi di includere questo manuale in caso di vendita prestito o in ogni alt...

Страница 14: ...tenze per l uso sicuro dell elettroutensile La pompa adatta solo per acqua pulita non per acque reflue domestiche o acqua contenente particelle solide o liquido corrosivo infiammabile Non utilizzare l...

Страница 15: ...gianali e o industriali La pompa progettata per funzionare in acque limpide con particelle di dimensioni sospese non superiori a 5 mm La pompa progettata per funzionare a temperature dell acqua non su...

Страница 16: ...causare danni al prodotto Non lasciare la pompa in funzione incustodita Non utilizzare la pompa quando persone o animali domestici sono in acqua VI PULIZIA E CONSERVAZIONE AVVERTIMENTO Prima di quals...

Страница 17: ...muovere il blocco e riavviare la pompa La pompa si avvia e si arresta frequentemente Perdite o intasamenti interni Sostituire il tubo che perde il tubo flessibile e i giunti pulire l ostruzione La pom...

Страница 18: ...ions Foto e illustrazioni senza valore contrattuale PRPVF500AUTO Fig 1 Fig 2 Fig 3 Pos FR EN IT 1 Embout du tuyau G3 4 Pipe spout G3 4 Bocca di erogazione G3 4 2 Vanne de contr le Control valve Valvol...

Страница 19: ...Description Descrizione POMPE VIDE FUT AUTOMATIQUE AUTOMATIC SUBMERSIBLE WATER PUMP POMPA AD ACQUA SOMMERSA AUTOMATICA R f rence Reference Articolo PRPVF500AUTO 511736 Mod le Type Model Modello Q55011...

Отзывы: