6.4- Trouble Shooting
Problem
Cause
Trouble Shooting
The pump stops working
suddenly
Power disconnected
Check fuse device and electrical
connection
Overheated
Disconnect from power source
and allow the pump to cool
before restarting
Foreign matter related blockage Remove blockage and restart
the pump
The pump starts and stops
frequently
Leakage or internal clogging
Replace the leaking pipe, hose
and joints, clean blockage
The pump runs, but no or little
water flow
Insufficient water (lower than
impeller)
Change working location or
position before restart the pump
Pipe or hose bent or damaged
Adjust/replace the hose/pipe
Inlet blockage
Clean the inlet
The pump cannot be shut down Control valve is gripped
Contact service centre
Our warranty conditions are available from our STAV department [*] and on our website.
Should you have any repair requests under the warranty, please contact your retailer or our STAV
[*] who will inform you on the procedure.
Should you have any parts and/or accessories request, you can contact our STAV [*] to ask for the
product exploded view by indicating our reference and the serial number or batch number appearing
on the nameplate.
[*] STAV = Technical and After-Sales Service department
STAV contact details
:
Ribimex, 56 Route de Paris, F-77340 Pontault-Combault.
Tel : 08 92 35 05 77 (0,34€/min ; only in France) ; email :
Internet Website: