background image

 

 

RexXer Tuning GmbH

 l Astheimer Str. 41 l DE - 65428 Rüsselsheim l Fon: +49 (0) 6142 / 793971-203 l Fax: +49 (0) 6142 / 793971-80 

www.rexxer.eu 

© by RexXer ECU Tuning 

 

Operation of the RexXer EVO 

„User“ 

 

WARNING!

 Before using this product, first read this manual carefully and 

retain  it  for  future  reference.  To  avoid  electrical  shock,  do  not  open  the 
case when the tool is connected. Refer any required servicing of product 
to RexXer ECU Tuning only!   
  

Makes  sure  that  the  battery  of  your  motorcycle  is  fully  loaded.  In 
models where the light burns continuously during the programming 
process,  you  can  optionally  use  a  battery  charger.  But  make 
absolutely sure that this is a linear charger, which never builds up 
voltage spikes. The RexXer EVO User could be damaged.  

  

Note: 

When delivered

 

the RexXer EVO User is ready for service and can 

be used immediately. The connection with the supplied software is in this 
step  optional.  If  you  want  to  connect  the  RexXer  EVO  User  later,  you 
need an active internet connection. 
 

The RexXer EVO User can be delivered in 2 different variants: 
 

1) 

Pre-installed with the corresponding Tuning-Mapping(s) 

2) 

Without the corresponding Tuning-Mapping(s) 

 

Please refer to your delivery note which variant applies to you.  

In  most  cases  the  RexXer  EVO  User  will  be  delivered  empty,  without 
pre-installed  Tuning-Mapping.  The  reason  is,  that  there  is  not  every 
Tuning-Mapping  compatible.  We  often  need  the  readout  Original-
Mapping from motorcycle to create the Tuning-Mapping. 
 
The following describes the procedure of both variants. 
 
1) Connect the supplied serial interface cable to the RexXer EVO User.  

Please  not  connect  the  USB  cable  in  addition  to  the  RexXer  EVO 
User*! 

 
2)  Connect  the  other  end  of  the  serial  interface  cable  to  the  diagnostic 
connector/service 

plug 

(OBD) 

of 

your 

motorcycle. 

 
3)  Now  connect  the  positive  terminal  of  the  battery  with  the  red-coded 
and  the  negative  terminal  with  the  black-coded  alligator  clip  (not 
available/necessary for all interface cables).  
 

Содержание EVO User

Страница 1: ...RexXer Tuning GmbH l Astheimer Str 41 l DE 65428 R sselsheim l Fon 49 0 6142 793971 203 l Fax 49 0 6142 793971 80 www rexxer eu by RexXer ECU Tuning Manual RexXer EVO User Update February 2018...

Страница 2: ...on 4 Product overview 7 Operation of the RexXer EVO User 8 READOUT AND SAVE THE ORIGINAL MAPPING 10 LOAD AND FLASH THE TUNING MAPPING 11 RESET PARAMETER AFTER FLASHING PROCESS 14 Service Diagnostic fu...

Страница 3: ...he RexXer EVO User the programmer which allows communication with the ECU of your motorcycle 2 USB 2 0 connection cable type A Mini B 5 pin to connect the RexXer EVO User to your computer 3 Serial int...

Страница 4: ...guide Safety This product has been designed with the highest concern for safety However any electrical device if used improperly has the potential for causing fire electrical shock or personal injury...

Страница 5: ...sunlight Do not leave the product or accessories in a car with the windows closed particularly in summer Do not expose the product or accessories to dust smoke or steam Do not allow liquid or small pa...

Страница 6: ...when the temperature goes up Cleaning Cleaning the exterior surface excluding the LCD screen Wipe gently with a soft cloth Do not use solvents or other chemicals to clear the exterior surface of the...

Страница 7: ...www rexxer eu by RexXer ECU Tuning 7 Product overview RexXer EVO User front side 1 LCD Display Touchscreen Display to use the recorded device software RexXer EVO User surface 1 USB Port To connect th...

Страница 8: ...this step optional If you want to connect the RexXer EVO User later you need an active internet connection The RexXer EVO User can be delivered in 2 different variants 1 Pre installed with the corres...

Страница 9: ...D this main menu will be opened automatically Tuning This menu group shows you the Tuning menu to read copy the ECU and also to flash write later Setup This menu point grants you access to a further s...

Страница 10: ...he original mapping of the ECU Figure 2 vehicle selection In this window you have to choose your connected vehicle Confirm your choice with the right pointing arrow First select the brand and after th...

Страница 11: ...ect the RexXer EVO User to the computer and save the Original Mapping with the function Download Data Figure 3 Download Data After reading out the Original Mapping with your RexXer EVO User you can do...

Страница 12: ...our RexXer EVO User 10 After the transfer has been completed the Original and Tuning Mapping are stored in the device memory of your RexXer EVO User Now you can disconnect the Device from the USB cabl...

Страница 13: ...the new usr file is transfered into the RexXer EVO User connect the device and the vehicle with the serial interface cable By using the menu item Tuning you can flash the ECU Answer the following que...

Страница 14: ...ng and after each reading of a mapping it s necessary to make the TPS reset and the sensor parameters reset not supported by all ECU types These functions can be found in the menu item Diagnosis Selec...

Страница 15: ...ire and thereby the insurance cover It s no longer permitted to use the vehicle on public roads CAUTION It is prohibited to make any changes and or improper interventions to the system RexXer Tuning G...

Страница 16: ...nctions If you have not yet changed the mapping by using the RexXer EVO User the device could not recognize your vehicle in that case select the menu item vehicle list In that menu point you can selec...

Страница 17: ...view about the current level of service diagnostic functions of the RexXer EVO support ECU types http www rexxer eu downloads rexxer_ecu_functions pdf The RexXer EVO User can only be used on the vehic...

Страница 18: ...he Windows 7 operating system as is required for the use of RexXer EVO User Note This applies not for Mac Linux or something similar The software is only based on Windows 1 To do this insert the USB s...

Страница 19: ...RexXer EVO User is not yet connected at this time to the USB cable and your computer If so please disconnect it now and also all other devices hardware which are connected via USB After installation...

Страница 20: ...ve to restore the Original Mapping into the vehicle ECU it was read out If this is not the case the RexXer EVO User will be locked and the unlocking is chargeable After the device was deleted correctl...

Страница 21: ...select or change the language click on the menu bar Click the Language icon below of Tools and select the appropriate language The new language is then stored permanently Figure 11 Language selection...

Страница 22: ...menu item Bikes of the menu groupe Available vehicles to get an overview of the avaliable vehicles of the RexXer EVO User Here are every available vehicle brands and models listed Furthermore you can...

Страница 23: ...t demonstrating all the steps that were taken with the device Figure 13 Download LOG Press START to download the LOG file and save this file on your computer After that send this file to us This file...

Страница 24: ...d types of ECU in the open state with a special process and so we are able to make it available as needed The data such as firmware number microprocessor type etc of the already read Original Mappings...

Страница 25: ...ps of the serial interface cable are connected incorrectly or one of the flat plug fuse for the diagnostic connector OBD from your bike is defective Is it allowed to connect the RexXer EVO User at the...

Страница 26: ...se chargeable What must be observed after an update of my RexXer EVO User page 14 The RexXer EVO User gets married with the vehicle identification number VIN stored in the engine control unit ECU This...

Отзывы: