Table 16: Axial piston unit malfunction table
Malfunction
Possible cause
Remedy
Rotational speed or torque cannot
be reached
Insufficient flow at hydraulic pump
Check function of the hydraulic pump
Minimum or maximum displacement set
incorrectly
Contact Bosch Rexroth Service
Control of the control device defective
Check control (machine/system manufacturer)
Insufficient pilot pressure or control pressure
Check pilot pressure or control pressure
Contact Bosch Rexroth Service
Malfunction of the control device or controller
of the axial piston motor
Contact Bosch Rexroth Service
Hydraulic fluid not in optimum viscosity range
Machine/system manufacturer:
check temperature range and use suitable
hydraulic fluid
Wear or mechanical damage to the axial piston
motor
Replace axial piston unit
Contact Bosch Rexroth Service
Wear or mechanical damage to the axial piston
pump
Replace hydraulic pump
Contact Bosch Rexroth Service
Wrong direction of rotation
Check function of the hydraulic pump
Machine/system manufacturer: Check correct
direction of rotation,
see chapter 7.4.1
"Preparation" on page 28
Excessive hydraulic fluid
temperature and housing
temperature
Excessive inlet temperature at the axial piston
unit
Machine or system manufacturer: inspect
system, e.g malfunction of the cooler,
insufficient hydraulic fluid in the reservoir
Wrong setting or malfunction of the
pressure
relief and pressure control valves
(e.g.
high-pressure relief valve, pressure cut-off,
pressure controller)
Optimize the adjustment of the
pressure relief
and pressure control valves
of the axial piston
unit and the pressure safeguarding in the
hydraulic system
Contact Bosch Rexroth Service
Contact machine/system manufacturer
Output speed too high
Contact machine/system manufacturer
Flushing flow of the flushing valve too low
Contact Bosch Rexroth Service
Wear of axial piston unit
Exchange axial piston unit, contact Bosch
Rexroth Service