Troubleshooting
Problem
Cause
Remedy
Blade slips or comes loose
Blade is not installed properly.
Install blade properly on
"SELI" heads, guide rollers and
pulley.
There is oil on blade.
Wipe away oil from blade and
reinstall.
There is oil on workpiece.
Wipe away oil from workpiece.
There is oil on pulleys,
guide rollers or "SELI" head
bearings.
Wipe away oil.
Tension lever is not set firmly
in place.
Turn tension lever to proper
position.
Rubber ring on pulley is worn.
Replace rubber ring on pulley.
(Have unit repaired or
serviced.)
There is resin or chips sticking
to rubber ring on pulley.
Wipe rubber ring with a rag.
Motor does not work
Overload protection unit has
been activated.
Use the procedure on Page 12
to reset.
Power plug has come out of
electric outlet.
Insert plug into outlet.
There is a short in the power
cord.
Have unit repaired or serviced.
Switch is faulty.
Have unit repaired or serviced.
Motor is faulty.
Have unit repaired or serviced.
Motor stops when cutting
Overload protection unit has
been activated.
Use the procedure on Page 12
to reset.
Line voltage is too low.
Reconnect to a 220 V power
supply.
Blade does not match material
being cut.
Replace blade with one that
matches the material being cut.
(Page 5)
Cutting load is not adjusted
properly.
Adjust the cutting load to match
the material being cut. (Page 5)
Workpiece moved during
cutting.
Make sure workpiece is
fastened securely in the V-
shaped groove.
- 19 -
Table 5