background image

DeltaSol

®

 

B Pro

© RESOL 04026 deltasol_b_pro.mon.pmd

Page 3/24

Universal system controller for solar- and heating systems

• housing in outstanding design and

compact dimensions, easy to
install

• multifunctional combined display

• 4  sensors Pt1000

2 standard relays

• user-friendly operation by simple

handling

• intuitive menu mode

• function control

• basic solar systems are provided

DeltaSol

®

 

B Pro

The controller RESOL 

DeltaSol

®

B Pro

is used for application in standard so-
lar thermal systems as well as in
heating and air conditioning systems
and persuades by its clear operation
concept.

A newly developed, multi-functional
display enables the user to simul-
taneously request two temperatures
(e.g. collector and store temperature).
Easy pictograms give the user clear

information on function and operating
status of the controller and the system.

This version is equipped with 4 sensor
inputs for PT1000 temperature sensors,
store temperature limitation and
manual mode (by menu). The central
element is the 3-key-field below the
display. The  newly  developed  combined
LC-display enables an intuitive and
reliable controller configuration as well
as a comprehensive visualisation of the

system status. The following standard
basic systems are provided:

1 :

2 separated 

T-circuits

2 :

2 stores with valve charge logic

3 : 

East/west collectors

4 :

 System with after heating of domestic

water

5 :

 2 stores with pump charge logic

Technical data

Housing: 

Plastic, PC-ABS and PMMA

Protction type: 

IP 20 / DIN 40050

Ambient temp.:

 0 ... 40 °C

Size: 

172 x 110 x 46 mm

Installation: 

wall mounting, mountig

into patch panels is possible

Display: 

LCD, multi-functional

combined display with 8 pictograms,two
2-digit text fields and two 4-digit 7-
segment displays as well as one 2-
coloured luminescent diode

Operation: 

by three pushbuttons in

the front of the housing

Functions: 

standard solar controller

with adjustable values: minimum-
maximum temperature limitation, frost
protection / cooling function, security
switch-off, function control according
to BAW-directions as well as solar
operating hour counter.

Inputs: 

4 temperature sensors Pt1000

Output: 

2 standard relays

Power supply:

210 ... 250 V~, 50 ... 60 Hz

Total power supply:

4 (2) A 250 V~

Degree of faulting:

 2

Rating surge voltage:

 2,5 kV

Temp. for ball pressure check:

75 °C

Mode of functioning:

Type 1.b

Electrostatical discharge can
cause damage of electronic
components.

Attention! Parts are high
voltage energized.

Содержание DeltaSol B Pro

Страница 1: ...DeltaSol B Pro www resol de RESOL DeltaSol B Pro Mounting Connection Handling Fault localization Examples Thanks for buying a RESOL Read this manual carefully to get the best perfomance from this unit...

Страница 2: ...Comissioning 11 5 Tips for fault localization 11 6 Examples 12 6 1 1 collector 1 store with heating reverse raising14 6 2 System with store charge by solid hot fuel boiler with heating reverse raising...

Страница 3: ...roller configuration as well as a comprehensive visualisation of the system status The following standard basic systems are provided 1 2 separated T circuits 2 2 stores with valve charge logic 3 East...

Страница 4: ...DeltaS eltaS eltaS eltaS eltaSol ol ol ol ol B Pro full kit 115 420 20 incl 3 temperatur sensors Pt1000 2 x FKP6 1 x FRP6 Please find detailed connection schemes for the shown systems in chapter 6 1 c...

Страница 5: ...und hole pitch 130 mm afterwards put the lower dowel 4 Fasten the housing at the underground 1 Installation Warning Switch off power supply before opening the housing 1 2 Electrical wiring The power s...

Страница 6: ...ameter cpl with fastening collar FK 21 or FR 21 Ensure good thermal contact of the sensor with the pipe work by cleaning the contact area and by applying heat conduction paste between sensor and pipe...

Страница 7: ...H2 Hours of Oparation Relay 2 FN FuNction 1 2 separated T circuits 2 2 stores 1 collector 2 stores 3 East West system 2 collectors 1 store 4 1 store with thermostat function 1 collector 1 store with...

Страница 8: ...This indication value can not be reset 3 2 3 Function FN FN 1 2 separate T circuits FN 2 2 stores 1 collector 2 stores FN 3 East west 2 collectors 1 store FN 4 1 store and thermostat function 1 collec...

Страница 9: ...ng for switch on temperature difference is 6 K and the switch off temperature difference is set to 4 K Please note Switch on temperature difference DO must be at least 1 K higher than the switch off t...

Страница 10: ...er days and ensures a thermal relief for the collectors and the heating medium The maximum collector temperature is set to 120 C by RESOL but it can be changed within the adjustment range of 100 C 190...

Страница 11: ...mperature is again underrun In doing so the store temperature can increase subordinated active store safety shutdown but only up to 95 C safety shutdown of the store If the store temperature is higher...

Страница 12: ...er heating TO TF the thermostat function is used as use of surplus energy If the 2nd relay output is activated in the display is shown 3 2 11Thermostat function TO TF System 4 FN 4 After heating use o...

Страница 13: ...uated at the base isolation plate and can be replaced by opening the cover of the housing spare fuse is enclosed in one of the accessory bags 2 Sensor faults If there is a malfunction due to a sensor...

Страница 14: ...ore temperature S4 sensor temperature S4 Heating circuit reverse temperature H1 Hours of operation relay 1 Control value H2 Hours of operation relay 2 Control value FN 1 1 FN1 2 separated T circuits D...

Страница 15: ...Solid fuel boiler emergency shut down temperature CX 1 120 switch on temperature for system cooling has no influence as the system cooling is deactivated OC 1 0 CN 1 10 60 60 C minimum temperature to...

Страница 16: ...ion CL 2 140 Solid fuel boiler emergency shut down temperature CX 2 120 Switch on temperature for system cooling has no influence as the system cooling is deactivated OC 2 0 CN 2 10 60 60 C Minimum te...

Страница 17: ...re temperature limitation of existing store CL 2 140 This adjustment channel has ne relevance in this case CX 2 120 Switch on temperature for system cooling has no influence as the system cooling is d...

Страница 18: ...emperature S2 Store temperature 1 S3 Sensor temperature S3 Store temperature 2 S4 Sensor temperature S4 Measuring sensor only without operational function H1 Hours of operation relay 1 Control value F...

Страница 19: ...llector temperature limitation CX 1 120 Maximum collector temperature CN 1 10 Minimum temperature limitation is deactivated OC 1 1 System cooling is activated DO 2 6 Switch on temperature difference s...

Страница 20: ...relay 1 Control value H2 Hours of operation relay 2 Control value FN 1 3 FN3 Solar system with East West collectors DO 1 6 Switch on temperature difference collector 1 DF 1 4 Switch off temperature di...

Страница 21: ...ry adjustment Channel FN 4 Channel Factory setting Change to Remark S1 Sensor temperature S1 Collector temperature S2 Sensor temperature S2 Lower store temperature TT Sensor temperature S3 Upper store...

Страница 22: ...ent Channel FN 4 Channel Factory setting Change to Remark S1 Sonsor temperature S1 Collector temperature S2 Sonsor temperature S2 Lower store temperature TT Sonsor temperature S3 Upper store temperatu...

Страница 23: ...DeltaSol B Pro RESOL 04026 deltasol_b_pro mon pmd Page 23 24...

Страница 24: ...eltaSol B Pro RESOL 04026 deltasol_b_pro mon pmd Page 24 24 Your wholesaler Notes Design and specifications are subject to change without notice Illustrations may differ slightly from production model...

Отзывы: