Resol DeltaSol B Pro Скачать руководство пользователя страница 2

DeltaSol

®

 

B Pro

© RESOL 04026 deltasol_b_pro.mon.pmd

Page 2/24

Impressum

This mounting- and operation manual including all parts is
copyrighted. Another use outside the copyright requires the
approval of RESOL - Elektronische Regelungen GmbH. This
especially applies for copies, translations, micro films and
the storage into electronic systems.

Editor: RESOL - Elektronische Regelungen GmbH

Important notice:

We took a lot of care over the texts and drawings of this
manual and to the best of our knowledge and consent. As
faults can never be excluded, please note:
Your own calculations and plans under consideration of the
current norms and DIN-directions should only be basis for
your projects. We don´t offer a guarantee for the com-
pleteness of the drawings and texts of this manual - they
only represent some examples.  They can only be used on
own risk. No liability is assumed for incorrect, incomplete
or false information and the resulting damages.

Errors and technical changes excepted

Contents

Security devices ................................................................. 2

Technichal data and function  survey ............................... 3

1.

Installation ............................................................. 4

1.1

Mounting ................................................................ 4

1.2

Electrical wiring .................................................... 4

2.

Sensor types .......................................................... 5

3.

Operation and function ......................................... 6

3.1

Adjustment switch ................................................ 6

3.2

Control parameter and indication channels ....... 6

3.2.1

Indication channles S1-S4 ..................................... 7

3.2.2

Indication channels H1 und H2 ............................ 7

3.2.3

∆∆∆∆∆

T-regulation .......................................................... 7

3.2.4

Maximum store temperture ................................. 7

3.2.5

Limit collector tempreture .................................. 8

3.2.6

Maximum collector temperature ......................... 8

3.2.7

Minimum collector tempreture ........................... 8

3.2.8

System cooling ....................................................... 9

3.2.9

Operation mode .................................................... 9

3.2.10 Oscillating charge .................................................. 9

3.2.11 Thermostat function ........................................... 10

3.2.12 LED blinking codes .............................................. 10

4.

Comissioning ........................................................ 11

5.

Tips for fault localization .................................... 11

6.

Examples .............................................................. 12

6.1

1 collector,1 store with heating reverse raising 14

6.2

System with store charge by solid hot fuel boiler

with heating reverse raising ................................ 15

6.3

Solar system with 1 collector, 1 store and after-

heating by solid hot fuel boiler ........................... 16

6.4

Solar system with 1 collector and 1 store with

heat exchange to existing store .......................... 17

6.5

Solar system with 1 collector and 2 stores

valve logic ............................................................. 18

6.6

Solar system with 1 collector and 2 stores

pump logic ............................................................ 18

6.7

East-/ west-collectors, 1 store ............................. 19

6.8

Solar system with 1 collector, 1 store and after-

heating .................................................................. 20

6.9

Standard solar system ......................................... 21

TRD 802

Steamboiler of group III,

TRD 402

Equipment of steamboiler systems with hot water

generators of group IV
DIN 1988, Part 1 – 8

Technichal rules for drinking water installation

DIN 4708, Part 3

Central warm water heating systems

DIN 4751, Part 1 + 2

Water heating systems

DIN 4753

Water heater and systems and for drinking water

DIN 4757, Part 1 – 4

Solar heating and solar thermal systems

DIN 18338

Roofing and roof sealing works

DIN 18339

Plumbers works

DIN 18451

Scaffolding works

VDE 0100

Set up of electrical operating supplies

VDE 0185

General rules for setting up overvoltage protection

systems
VDE 0190

Main potential equalization of electrical systems

DIN 18381

Gas-, water- and sewage installation systems

DIN 18382

Electrical cable- and line systems in housings

HeizAnlV

Heating system regulation

Safety regulations:

Please read the following
information carefully before
installing and operating the
controller. In this way damage
to the solar system by wrong
installation will be avoided.
Please observe that the
mounting is adapted to the
characteristics of the building,
that the local regulations are
respected and is conform to
the technical rules.

Содержание DeltaSol B Pro

Страница 1: ...DeltaSol B Pro www resol de RESOL DeltaSol B Pro Mounting Connection Handling Fault localization Examples Thanks for buying a RESOL Read this manual carefully to get the best perfomance from this unit...

Страница 2: ...Comissioning 11 5 Tips for fault localization 11 6 Examples 12 6 1 1 collector 1 store with heating reverse raising14 6 2 System with store charge by solid hot fuel boiler with heating reverse raising...

Страница 3: ...roller configuration as well as a comprehensive visualisation of the system status The following standard basic systems are provided 1 2 separated T circuits 2 2 stores with valve charge logic 3 East...

Страница 4: ...DeltaS eltaS eltaS eltaS eltaSol ol ol ol ol B Pro full kit 115 420 20 incl 3 temperatur sensors Pt1000 2 x FKP6 1 x FRP6 Please find detailed connection schemes for the shown systems in chapter 6 1 c...

Страница 5: ...und hole pitch 130 mm afterwards put the lower dowel 4 Fasten the housing at the underground 1 Installation Warning Switch off power supply before opening the housing 1 2 Electrical wiring The power s...

Страница 6: ...ameter cpl with fastening collar FK 21 or FR 21 Ensure good thermal contact of the sensor with the pipe work by cleaning the contact area and by applying heat conduction paste between sensor and pipe...

Страница 7: ...H2 Hours of Oparation Relay 2 FN FuNction 1 2 separated T circuits 2 2 stores 1 collector 2 stores 3 East West system 2 collectors 1 store 4 1 store with thermostat function 1 collector 1 store with...

Страница 8: ...This indication value can not be reset 3 2 3 Function FN FN 1 2 separate T circuits FN 2 2 stores 1 collector 2 stores FN 3 East west 2 collectors 1 store FN 4 1 store and thermostat function 1 collec...

Страница 9: ...ng for switch on temperature difference is 6 K and the switch off temperature difference is set to 4 K Please note Switch on temperature difference DO must be at least 1 K higher than the switch off t...

Страница 10: ...er days and ensures a thermal relief for the collectors and the heating medium The maximum collector temperature is set to 120 C by RESOL but it can be changed within the adjustment range of 100 C 190...

Страница 11: ...mperature is again underrun In doing so the store temperature can increase subordinated active store safety shutdown but only up to 95 C safety shutdown of the store If the store temperature is higher...

Страница 12: ...er heating TO TF the thermostat function is used as use of surplus energy If the 2nd relay output is activated in the display is shown 3 2 11Thermostat function TO TF System 4 FN 4 After heating use o...

Страница 13: ...uated at the base isolation plate and can be replaced by opening the cover of the housing spare fuse is enclosed in one of the accessory bags 2 Sensor faults If there is a malfunction due to a sensor...

Страница 14: ...ore temperature S4 sensor temperature S4 Heating circuit reverse temperature H1 Hours of operation relay 1 Control value H2 Hours of operation relay 2 Control value FN 1 1 FN1 2 separated T circuits D...

Страница 15: ...Solid fuel boiler emergency shut down temperature CX 1 120 switch on temperature for system cooling has no influence as the system cooling is deactivated OC 1 0 CN 1 10 60 60 C minimum temperature to...

Страница 16: ...ion CL 2 140 Solid fuel boiler emergency shut down temperature CX 2 120 Switch on temperature for system cooling has no influence as the system cooling is deactivated OC 2 0 CN 2 10 60 60 C Minimum te...

Страница 17: ...re temperature limitation of existing store CL 2 140 This adjustment channel has ne relevance in this case CX 2 120 Switch on temperature for system cooling has no influence as the system cooling is d...

Страница 18: ...emperature S2 Store temperature 1 S3 Sensor temperature S3 Store temperature 2 S4 Sensor temperature S4 Measuring sensor only without operational function H1 Hours of operation relay 1 Control value F...

Страница 19: ...llector temperature limitation CX 1 120 Maximum collector temperature CN 1 10 Minimum temperature limitation is deactivated OC 1 1 System cooling is activated DO 2 6 Switch on temperature difference s...

Страница 20: ...relay 1 Control value H2 Hours of operation relay 2 Control value FN 1 3 FN3 Solar system with East West collectors DO 1 6 Switch on temperature difference collector 1 DF 1 4 Switch off temperature di...

Страница 21: ...ry adjustment Channel FN 4 Channel Factory setting Change to Remark S1 Sensor temperature S1 Collector temperature S2 Sensor temperature S2 Lower store temperature TT Sensor temperature S3 Upper store...

Страница 22: ...ent Channel FN 4 Channel Factory setting Change to Remark S1 Sonsor temperature S1 Collector temperature S2 Sonsor temperature S2 Lower store temperature TT Sonsor temperature S3 Upper store temperatu...

Страница 23: ...DeltaSol B Pro RESOL 04026 deltasol_b_pro mon pmd Page 23 24...

Страница 24: ...eltaSol B Pro RESOL 04026 deltasol_b_pro mon pmd Page 24 24 Your wholesaler Notes Design and specifications are subject to change without notice Illustrations may differ slightly from production model...

Отзывы: