– 43 –
Panic Keys
(For Manually Activating Silent and/or Audible Alarms)
Using Panic Keys
Your system may have been programmed to use special key combinations to
manually activate panic functions. The functions that might be programmed are
Silent Emergency, Audible Emergency, and Personal Emergency. See your
installer for the function(s) that may have been programmed for your system.
Active Panic Functions
(Your installer should note which
function(s) is active in your
system.)
Keys
Zone Function
1 and *
995
3 and #
996
* and #
999
A
995
B
999
C
996
To use a paired key panic function,
simply press both keys of the assigned
pair at the same time.
If your keypad(s) have lettered keys for
panic functions, press the designated
key and hold down for at least 2 seconds
to activate the panic function.
A silent emergency
sends a silent alarm signal to the central station, but there
will be no audible alarms or visual displays.
An audible emergency
sends an emergency message to the central station (if
connected) and will sound a loud, steady alarm at your keypad
and
at any
external sounders that may be connected (
ALARM
plus a zone number would
also be displayed).
A personal emergency alarm sends an emergency message to the central
station
(if connected) and will sound at Keypads, but not at external Notification
Appliance Circuits
. (
ALARM
plus a zone number would also be displayed.)