Fasten the bottom of the T-Slotted Brackets to Support Arm
A. Slide T-Bolt (F) through same slot as previous step. The distance that the bolt should slide
depends on the angle that the T-Slotted Bracket (A) was fastened to the top L-Channel
(B). Usually anywhere from 150mm to 250mm (6in to 9.8in) although it can exceed that if
necessary.
B. The back planes of both L-Channels (B) should be parallel and flush to the pole. Achieving
this may require reorienting the T-Slotted Bracket (A). It is recommended to fasten the
Support Arms (D) to the T-Slotted Brackets temporarily until you can attempt to orient the
assembly on the desired pole.
C. Once the assembly has been temporarily fastened, and is now near the pole, attempts
can be made to attach the Pole Mount to the Pole.
D. If the backs of the L-Channels (B) are not flush to the pole surface, adjust the Support Arm
(D) angle as needed until the desired angle is achieved.
E. Once desired angle has been achieved fasten the Support Arm (D) to T-Slotted Bracket
(A) with a small Nut (K).
Figure 5
D
A
F
K
Содержание Off-Grid Kit
Страница 8: ...8 Wiring 1 Unscrew battery terminals and connect battery connections...
Страница 10: ...10 4 Insert battery remote sensor block terminal and connect wires POLARITY SENSITIVE...
Страница 16: ...16...
Страница 17: ...17 Repeat for each Z Bracket in the set at each corner...
Страница 18: ...18...
Страница 20: ...20...
Страница 21: ...21 NOTE Orient panel in level plumb layout as desired before fixing in position...
Страница 23: ...23 Repeat for all brackets NOTE Seal around all edges of bracket and screws...
Страница 26: ...26 NOTE Mark all holes locations in this step as the panel must be removed for well nut insertion...
Страница 27: ...27...
Страница 29: ...29 NOTE Orient panel in level plumb layout as desired before fixing in position...
Страница 30: ...30 Repeat for all fasteners NOTE Screw has compressed and expanded the well nut binding into the roof material...
Страница 36: ...36 NOTE Start lag bolt threading by hand...
Страница 37: ...37 Rail System Construction 2 1...
Страница 38: ...38 4 3...
Страница 39: ...39 6 5...
Страница 40: ...40 Repeat for all continuous rail sets Rail Seating 7 1...
Страница 41: ...41 3 2...
Страница 42: ...42 5 4...
Страница 43: ...43 Panel Securement WARNING End clamps must be installed a minimum of 1 30 mm from the rail edges 6 1...
Страница 44: ...44 3 2...
Страница 45: ...45 5 4 NOTE Ensure that the End Clamp is spaced a minimum distance of 1 25 from rail end face...
Страница 46: ...46 Continue mid clamp procedure for each additional panel 6 7...
Страница 55: ...55 Figure 7 Figure 8...